Commands and Queries Reference

Alphabetical reference

ILIM

program an

upper limit on subsequent programming of current

 

settings for the Power Module.

 

 

Syntax

ILIM <ch>,<value>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the value to become the new upper limit for ISET

 

 

programming. The upper value of the programmed

 

 

value is IMAX.

 

 

Category

Settings

Type: Sequential

ILIM?

return the current value of the upper limit on ISET programming. The

 

response is a <value>.

 

 

Syntax

ILIM? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Settings

Type: Sequential

ILOAD?

return output

current measurement of the Power Module. The

 

response is a <value> (same as the IOUT? query).

 

 

Syntax

ILOAD? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Read-back

Type: Sequential

ILOW

program the lower window warning level for the output current of the

 

Power Module.

 

 

Syntax

ILOW <ch>,<value>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the value to be set as the lower window warning

 

 

level for the output current. The upper limit of the

 

 

programmed value is ISET.

 

 

Category

Warnings

Type: Sequential

ILOW?

return the current settings for the lower window warning level of the

 

output current of the Power Module. The response is a <value>.

 

Syntax

ILOW? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

warnings

Type: Sequential

IMAX?

return the value of the Power Module’s output current rating.

 

Syntax

IMAX? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Settings

Type: Sequential

XMP 2600 Programming Manual rev. 1.1

51

Page 64
Image 64
Xantrex Technology XMP 2600 manual Return output Current measurement of the Power Module