Commands and Queries Reference |
| Alphabetical reference | |||
CESE | assign new value to the Channels Event Status Enable Register. Re- | ||||
|
| calculates <rqs> and <ist>. |
|
| |
|
| Syntax | CESE <int> |
|
|
|
| Parameters | the value to be assigned to the Register - a decimal | ||
|
|
| number in the range 0 to 255 representing bits in the | ||
|
|
| Register. |
|
|
|
| Category | Status | Type: Sequential | |
|
|
|
| ||
|
| Recalculation is performed for ALL the Channels including those with no |
| ||
|
| Power Module installed. |
|
|
|
|
|
|
|
|
|
CESE? | return the value of the Channels Event Status Enable Register. The | ||||
|
| value returned is a decimal number in the range 0 to 255 representing | |||
|
| the bits of the Register. |
|
| |
|
| Syntax | CESE? |
|
|
|
| Parameters | none |
|
|
|
| Category | Status | Type: Sequential | |
CHNL? | return two decimal numbers, in the range 0 to 255. Each bit of the | ||||
|
| reply represents a channel. A bit value of “0” means that no Power | |||
|
| Module is installed in that channel. A bit value of “1” means that a | |||
|
| Power Module is installed in that channel. The reply is a | |||
|
| with its high order byte sent first. |
|
| |
|
| Syntax | CHNL? |
|
|
|
| Parameters | none |
|
|
|
| Category | System | Type: Sequential | |
CLR | returns the XMP 2600 to its power on state: perform a BUFCLR, send | ||||
|
| a Fault Reset Command to all faulty Power Modules, if Primary was | |||
|
| shut down then try to revive it and update Primary status, clear System | |||
|
| Error Code and channels status structures, Initialize or Retain Power | |||
|
| Modules Settings, return the Front Panel Display to Normal Status | |||
|
| Mode. Does not clear the System Status Structure | |||
|
| Syntax | CLR |
|
|
|
| Parameters | none |
|
|
|
| Category | System | Type: Sequential |
XMP 2600 Programming Manual rev. 1.1 | 45 |