Commands and Queries Reference

 

Alphabetical reference

RIPL?

return the current programmed output ripple for the Power Module.

 

The result is two decimal numbers: the first being the level (0t o 2)

 

and the second being the frequency (1 to 7).

 

Syntax:

RIPL?

 

 

Parameters

none

 

 

Category

Settings

Type: Sequential

ROM?

return a string identifying the XMP 2600. The result is “XMP 2600

 

x.xx dd/mm/yy” where: x.xx is the firmware revision code and

 

dd/mm/yy is the firmware date code.

 

 

Syntax

ROM?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

SEQ

start / stop sequence program execution.

 

 

Syntax

SEQ <int>

 

 

Parameters

a value of “0” will stop and a value of “1” will start

 

 

the Sequence Program.

 

 

Category

System

Type: Sequential

SEQ?

return the current state of the Sequence Program. The result is a single

 

decimal number of value “0” if the program is not running. If the

 

program is running then the result will have two elements: the first is

 

the number (1 to 99) of the step being executed and the second is the

 

amount of time left until the step’s operation will be performed

 

(h:mm:ss).

 

 

 

Syntax

SEQ?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

SEQCLR

clear all Sequence Program Steps (only if program is not running).

 

Syntax

SEQCLR

 

 

Parameters

none

 

 

Category

System

Type: Sequential

XMP 2600 Programming Manual rev. 1.1