Alphabetical reference

 

Commands and Queries Reference

VLIM?

return the current value of the upper limit on VSET programming. The

 

response is a <value>.

 

 

Syntax

VLIM? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Settings

Type: Sequential

VLOAD?

return load voltage measurement of the Power Module. The response

 

is a <value>. If auto-polarity is enabled, negative output values will be

 

preceded with a minus sigh.

 

 

Syntax

VLOAD? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Read-back

Type: Sequential

VLOW

program the lower window warning level for the load voltage of the

 

Power Module.

 

 

 

Syntax

VLOW <ch>,<value>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the value to be set as the lower window warning

 

 

level for the load voltage. The upper limit of the

 

 

programmed value is VSET.

 

 

Category

Warnings

Type: Sequential

VLOW?

return the current settings for the lower window warning level of the

 

load voltage of the Power Module. The response is a <value>.

 

Syntax

VLOW? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

warnings

Type: Sequential

VMAX?

return the value of the Power Module’s output voltage rating.

 

Syntax

VMAX? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Settings

Type: Sequential

VOUT?

return output

voltage measurement of the Power Module. The

 

response is a <value>. If auto-polarity is enabled, negative output

 

values will be preceded with a minus sigh.

 

 

Syntax

VOUT? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Read-back

Type: Sequential

66

XMP 2600 Programming Manual rev. 1.1

Page 79
Image 79