Commands and Queries Reference

 

Alphabetical reference

STEP

program a Sequence Program Step.

 

Syntax

STEP <int>,<step_delay>,<int>[,<int>]

 

Parameters

the number of the Step to be programmed.

 

 

the amount of time to delay the Step Operation.

 

 

General format: h:mm:ss, where h=hour,

 

 

mm=minutes and ss=seconds. Step_delay values can

 

 

be shortened to “h:mm:” or “h::”. Value is limited to

 

 

9:59:59.

 

 

the operation to be performed by the Step. A

 

 

decimal number in the range 0 to 14:

 

 

0 = STEP

 

 

1 to 10 = RCL 0 to RCL 9

 

 

11

= GOTO

 

 

12

= OFF

 

 

13

= ON

 

 

14

= STOP

the forth parameter is required for operation code “11” (GOTO) only. In this case, it is a decimal number in the range 1 to 99 representing the Step number to “GOTO”.

 

Category

System

Type: Sequential

STEP?

return the programmed STEP delay and operation. The result has 2 to

 

3 elements: the first is the Step_Delay (“h:mm:ss”) and the second

 

element is the Operation code (see STEP command - a decimal

 

number in the range 0 to 14). If the operation is “GOTO” then a third

 

element will be returned: a decimal number in the range 1 to 99,

 

standing for the number of the Step to GOTO.

 

 

Syntax

STEP? <int>

 

 

Parameters

the number of the Step to be reported.

 

Category

System

Type: Sequential

STO

stores settings of all the Power Modules.

 

 

Syntax

STO <int>

 

 

Parameters

a decimal number in the range 0 to 9 specifying the

 

 

storage number the XMP 2600 will store the settings

 

 

in.

 

 

Category

System

Type: Sequential

XMP 2600 Programming Manual rev. 1.1

61

Page 74
Image 74
Xantrex Technology XMP 2600 manual = Goto, = Off, = Stop