RIM BAR
A I.D.
3 HP
ELECTRIC
MOTOR
C

C

L

B
H
CH C
A
RECOMMENDED FLOOR
SLOPE 1 INCH PER 4 FEET
PIPE DRAIN RECOMMENDED
MINIMUM VALVE SIZE PLUS 1"
13"
6" RECOMMENDED
FLOOR DRAIN
3" DIA. BUTTERFLY VALVE
12" X 24"
RECOMMENDED
FLOOR DRAIN
3" MIN
CLEARANCE
8 3/4"
E
(COVER
FULLY
OPEN)
SPRING ASSIST
COVER (FULLY
OPEN AT 90 )
D
WALL
WALL
M M
F
L
P
N
P
3" REF.
10 3/8
G
18 3/8Q
K
MODEL
HA-MKGL-60-CC
HA-MKGL-80-CC
HA-MKGL-100-CC
A
29 1/2"
33"
35 1/2"

DIMENSIONS

B
48 1/4"
51 3/4"
54 1/4"
C
50"
58"
60 1/2"
D
36 1/2"
39"
40 3/4"
E
83"
90"
96"
F
13 1/8"
14 7/8"
16 1/8"
G
34 5/8"
35 15/16"
37 1/8"
K
23 7/8"
24 5/8"
25 1/4"
L
19 1/8"
20 7/8"
22 1/8"
M
10 3/32"
11 17/32"
12 3/4"
N
24"
26"
27 1/4"
P
9 3/4"
9 3/4"
11"
Q
17 7/8"
18 5/8"
19 1/4"
NOTES: CLEVELAND RANGE EQUIPMENT IS BUILT TO COMPLY WITH APPLICABLE STANDARDS FOR MANUFACTURERS. INCLUDED AMONG THOSE APPROVAL AGENCIES ARE: UL, A.G.A., NSF, ASME/N.BD., CSA, CGA, ETL, AND OTHERS.
INSTALLATIONS OF BACK FLOW PREVENTERS, VACUUM BREAKERS AND OTHER SPECIFIC CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER AND INSTALLER.
ALL VERTICAL DIMENSIONS SHOWN ARE MINIMUM. FEET ARE ADJUSTABLE TO +1" MAXIMUM.
MANUFACTURER MUST BE NOTIFIED IF UNIT WILL BE OPERATING ABOVE 2000' ALTITUDE.
CONSULT FACTORY FOR MANUFACTURED GAS.
Cleveland Range reserves right of design improvement or modification, as warranted.
A
VOLTS: 208/240
PHASE: 3
AMPS: 15
FREQ: 60 HZ
ELECTRICAL
SUPPLY
TYPE: NAT or LP
BTU PER CU. FT.:
1000 (NAT), 2500 (LP)
SUPPLY PRESSURE:
4" to 14" W.C.
BTU RATINGS:
190,000 per hour
RIGHT: 3", LEFT: 3"
REAR: 3"
(ALLOW 12" SPACE
MINIMUM ON LEFT
SIDE FOR SERVICE)
60 GAL -
940 LBS.
428 KG.
80 GAL -
1030 LBS.
469 KG.
100 GAL -
1110 LBS.
505 KG.
APPROX.
SHIPPING
WEIGHTS
GAS SUPPLY
(PIPING 3/4" NPT)
CLEARANCE
APPROVALS
PRESSURE:
90 - 100 PSI
(only required for optional 3" dia.
piston draw-off valve)
AIR SUPPLY (PIPING 1/2" NPT)
HOT & COLD
WATER
AGA CGA NSF
H C
1/2" NPT CONNECTION
40-60 PSI PRESSURE
5/8"Ø,
2 HOLES
ON
4" B.C.D.

SOLID

FOOT DETAIL

5
1/2"
3/8"
1" (MAX. ADJUSTMENT)
2"
H C
SPECIFICATION DRAWING -TILTING MODELS