INSTALLATION

GENERAL

Installation of the kettle must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of product could cause injury or damage.

This equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL, and others. Many local codes exist, and it is the responsibility of the owner/installer to comply with these codes.

Observe all clearance requirements to provide proper make- up air flow as well as sufficient clearance for servicing.

Dimensions and clearance specifications are shown on the specification sheet and in the Clearance Requirements section. Do not install kick plates or otherwise obstruct the flow of combustion and ventilation air.

Check rating plate to ensure that kettle has been equipped to operate with the type of gas available at the installation.

VENTILATION

Gas fired kettles are only to be installed under a ventilation hood in a room which has provisions for adequate make up air. Further information can be obtained by referring to the U.S.A. National Fire Protection Associations NFPA96 regulations. These standards have also been adopted by the National

Building Code in Canada.

INSPECTION

Before unpacking visually inspect the unit for evidence of damage during shipping. If damage is noticed, do not unpack the unit, follow shipping damage

instructions.

SHIPPING DAMAGE

INSTRUCTIONS

If shipping damage to the unit is discovered or suspected, observe the following guidelines in preparing a shipping damage claim.

1.Write down a description of the damage or the reason for suspecting damage as soon as it is discovered. This will help in filling out the claim forms later.

2.As soon as damage is discovered or suspected, notify the carrier that delivered the shipment.

3.Arrange for the carrier's representative to examine the damage.

4.Fill out all carrier claims forms and have the examining carrier sign and date each form.

CLEARANCE REQUIREMENTS

This unit must be installed in accordance with the clearances shown on the rating label which is adhered to the unit.

FOR YOUR SAFETY. Keep the appliance area free and clear of combustible materials.

KETTLE

1.When removing the kettle from the platform, handle with care to prevent scratching or any other damage. It is imperative that the kettle be level before bolting to the floor. This will prevent any twist or out of roundness to the kettle and will stop deflection of the agitator. Make sure the kettle is securely bolted to the floor and follow the procedure listed below:

Raise the flange on the leg under the motor so that it sets freely (stationary kettles only).

Position the kettle in its permanent location, check clearances and level the kettle by turning the adjustable feet.

Lower the flange or flanges under the motor channel. Over adjustment, whether up or down, could cause misalignment and cause damage to the agitator drive shaft and hub (stationary kettles only).

2.Next you must check the alignment of the drive shaft for a uniform clearance between the hub and the shaft. In order to check for clearance you must remove the seal cover plate and pull the seal back. you can check the distance for clearance by using a wire feeler gauge.

3.If adjustment is required for side direction, loosen the motor bolts, center the shaft and retighten.

If vertical alignment is needed, loosen the motor bolts and add a shim to raise or remove a shim to lower. Retighten bolts. When this is complete, check to see if the agitator shaft coupling slides freely for easy removal of the agitator.

4.Once positioned and leveled, permanently secure the kettle’s flanged feet to the floor using 1/2 x 2 I/2 inch lag bolts and floor anchors (supplied by the installer). Two bolts per leg are required to secure each of the flanged feet.

Page 4
Image 4
Cleveland Range HA-MKGL-60-CC manual General, Ventilation, Inspection, Shipping Damage Instructions, Clearance Requirements

HA-MKGL-60, HA-MKGL-80-CC-T, HA-MKGL-80-CC, HA-MKGL-100, HA-MKGL-80-T specifications

The Cleveland Range HA-MKGL series includes several models designed for high-performance cooking in commercial kitchens. Among these are the HA-MKGL-100-CC, HA-MKGL-100-CC-T, HA-MKGL-60-T, HA-MKGL-80, and HA-MKGL-60-CC. These cookers are ideal for institutions such as schools, hospitals, and restaurants that require reliability and efficiency.

One of the main features of the Cleveland Range HA-MKGL series is the SmartSteam technology. This innovation allows for precise control of cooking temperatures and humidity levels, ensuring that food is cooked evenly while retaining moisture and flavor. This technology is particularly beneficial for steaming vegetables, seafood, and rice, making it an excellent choice for chefs who prioritize quality and taste.

Another notable characteristic is the programmable controls that allow for set-and-forget operation. These controls enable chefs and kitchen staff to input specific cooking times and temperatures, reducing labor costs and minimizing the risk of overcooking. With the integration of user-friendly interfaces, staff members can efficiently operate the equipment without extensive training.

The HA-MKGL-100-CC and HA-MKGL-100-CC-T models feature a large cooking capacity, making them capable of handling high volume meal production. The added T in the model designation indicates a turbo model, which is designed for accelerated cooking speeds, catering to the needs of busy kitchens. The HA-MKGL-60-T and HA-MKGL-80 models also offer robust cooking capabilities while optimizing space in smaller kitchens.

Durability is another hallmark of the Cleveland Range HA-MKGL series. Constructed from high-quality stainless steel, these cookers are built to withstand the rigorous demands of a busy kitchen environment. The easy-clean design further enhances their usability, as chefs can quickly maintain hygiene and cleanliness in their cooking areas.

The energy efficiency of the Cleveland Range HA-MKGL series also stands out, contributing to low operational costs. With a focus on sustainability, these models minimize energy consumption without sacrificing performance, allowing institutions to save on utility bills while being environmentally conscious.

In summary, the Cleveland Range HA-MKGL series, including the HA-MKGL-100-CC, HA-MKGL-100-CC-T, HA-MKGL-60-T, HA-MKGL-80, and HA-MKGL-60-CC, represents cutting-edge technology in commercial cooking. Their programmable controls, SmartSteam technology, high capacity, durability, and energy efficiency make them ideal for professionals looking to enhance their culinary output while maintaining consistent quality in their food preparation.