GAS
It is recommended that a sediment trap (drip leg) be
installed in the gas supply line. If the gas pressure
exceeds 14” water column, a pressure regulator must
be installed, to provide a maximum of 14” water column
gas pressure to the gas control valve.
Connect the gas supply piping to the input side of the
gas control valve. Location and pressure data are
shown on the specification sheet.
Installation must be in accordance with local codes
and/or the National Fuel Gas Code ANSI Z223.1-1988
(USA) or the Installation Codes for Gas Burning
Appliances and Equipment CANI B149.1 and B149.2
(Canada). Use a gas pipe joint compound which is
resistant to L.P. gas. Test all pipe joints for leaks with
soap and water solution. Ensure that the gas pressure
regulator is set for the manifold pressure indicated on
the gas rating plate.
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psi (3.45 kPa). The appliance must be
isolated from the gas supply piping system by closing
its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.45 kPa).
ELECTRICAL
Electrical installation must be in accordance with local
codes and/or the National Electric Code ANSI/NFPA 70-
1990 (USA) or the Canadian Electrical Code CSA
Standard C22.1 (Canada). The kettle must be
electrically grounded by the installer.
A separate fused disconnect switch must be supplied
and installed in the high voltage electrical supply line.
The wire gauge size and electric supply must match the
power requirements specified on the kettle’s rating
plate. The waterproof conduit enclosed permanent
copper wiring must be adequate to carry the required
current at the rated voltage. Refer to the specification
sheet or rating label for electrical specifications and
location of electrical connections.
Remove the screws securing the component cover
(located to the left rear side of kettle), and remove the
cover. A wiring diagram is affixed to the inside of the
cover. Feed conduit enclosed permanent copper wiring
through the cut-out in the bottom of the console and
fasten to the terminal block. Fasten the ground wire to
the ground lugs connected to the frame, beside the
terminal block. Replace the console cover and secure it
with the screws.
WATER
The sealed jacket of the gas-fired kettle is precharged
with the correct amount of a water-based formula, and
therefore, no water connection is required to the kettle
jacket.
CLEANING
After installation the kettle must be thoroughly cleaned
and sanitized prior to cooking.
WARRANTY
Our Company supports a worldwide network of
Maintenance and Repair Centres. Contact your nearest
Maintenance and Repair Centre for replacement parts,
service, or information regarding the proper
maintenance and repair of your cooking equipment
In order to preserve the various agency safety
certification (UL, A.G.A., NSF, ASME/Ntl. Bd., etc.), only
factory-supplied replacement parts should be used. The
use of other than factory supplied replacement parts will
void warranty.