43 DEC1 Deceleration Time #1 0.10-600 3 s 1 1
44 ACC2 Acceleration Time #2 0.10-600 1 s 2
45 DEC2 Deceleration Time #2 0.10-600 1 s 2
46 DECTL Torq. Limit Response Time 0.10-30 1 s 2
47 DCBRK DC Brake Time 0-5 0.2 s 2
48 DCVLT DC Brake voltage 0-15 Note1 % 2
51 VSEL V/Hz Characteristic Selector 0-5 0 --- 2 2
52 BOOST Torque Boost 0-25 Note 1 % 1 8
53 FKNEE V/Hz Knee Frequency 26-640 60 Hz 2 75
54 SKBND Skip Fresq. Hysteresis Band 0.20-20 1 Hz 2
55 SK1 Skip Frequency #1 0.00-400 0 Hz 2
56 SK2 Skip Frequency #2 0.00-400 0 Hz 2
57 SK3 Skip Frequency #3 0.00-400 0 Hz 2
58 SK4 Skip Frequency #4 0.00-400 0 Hz 2
59 MVOLT Rated Motor Voltage 185-480 Note 1 V 2
61 LTLF Load Torq. Limit Forward 5-150 150 % 2
62 LTLR Load Torq. Limit Reverse 5-150 150 % 2
63 RTLF Regenerative Torq. Limit FWD 5-110 80 % 2
64 RTLR Regenerative Torq. Limit REV 5-110 80 % 2
65 SLIP Slip Compensation 0-10* 0 % 1
66 STAB Current Stability 0-5 2 --- 2
67 TOL Timed Overload Trip Point 0-100 0 % 2 100
68 NRST Restart Number 0-8 0 --- 2
69 DRST Restart Delay 0-60* 0 s 2
6C TOLC Timed Overload Characteristic 0-7 0 --- 2
71 METER Analog Meter Output 0-7 1 --- 1
72 ST1 Auxiliary Output #1 0-11 6 --- 2
73 ST2 Auxiliary Output #2 0-11 3 --- 2
74 ST3 Auxiliary Output #3 0-11 7 --- 2
75 STR Auxiliary Relay (Fault) 0-11 2 --- 2 3
81 PRGNO Special Program Number 0-65000 0 --- 2 2
82 START Inverter Start Options 0-7 0 --- 2
83 PWM Carrier Frequency Selector 0-1 0 --- 2 1
84 DISP Display Option Full Setting 0-65000 0 --- 2
85 UNITS Display Units ALPHA RPM_1 --- 2
86 LANG Display Language 0-3 0 --- 2
87 ACODE Security Access Code 0-999 0 --- 2
A2 RATIO Master Slave Speed Ratio (Note 2) 50-2000 100 % 2
B1 OPTNO Option Board Number 0-6 0 --- 2
Cx CNTLx Event Control (1-9) BINARY (8) 0 --- 2
Ex ECNTx Event Counts (1-9) 0-65535 0 --- 2
Bolded areas indicate Cleveland modifications of factory settings.