RECOMMENDED
FLOOR DRAIN

12"

M

H

J

A

F

7 3/4"

G

28" L

16"

RECOMMENDED FLOOR
SLOPE 1 INCH PER 4 FEET
PIPE DRAIN RECOMMENDED
MINIMUM VALVE SIZE PLUS 1"

T

5" MIN
CLEARANCE
E
(COVER
FULLY
OPEN)

S

B

A
SPRING ASSIST
COVER (FULLY
OPEN AT 90 )
3 HP
ELECTRIC
MOTOR

A I.D.

C

D

6" RECOMMENDED
WALL
WALL
FLOOR DRAIN
A
MODEL
HA-MKGL-60-TCC
HA-MKGL-80-TCC
HA-MKGL-100-TCC
A
29 1/2"
33"
35 1/2"

DIMENSIONS

B
48 1/4"
51 3/4"
54 1/4"
C
61 5/8"
65 3/8"
68 3/8"
D
46 3/4"
52"
55"
E
93"
98"
104"
F
27 3/4"
30 3/4"
32 3/4"
G
42"
45 11/16"
48 3/16"
H
30 5/8"
33 5/8"
35 5/8"
J
78"
84"
95 5/8"
L
10 3/8"
11 7/16"
11 5/8"
M
53"
57"
66"
S
19 1/4"
20 3/4"
22"
T
24 1/2"
26 3/16"
27 5/8"
A
NOTES: CLEVELAND RANGE EQUIPMENT IS BUILT TO COMPLY WITH APPLICABLE STANDARDS FOR MANUFACTURERS. INCLUDED AMONG THOSE APPROVAL AGENCIES ARE: UL, A.G.A., NSF, ASME/N.BD., CSA, CGA, ETL, AND OTHERS.
INSTALLATIONS OF BACK FLOW PREVENTERS, VACUUM BREAKERS AND OTHER SPECIFIC CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER AND INSTALLER.
ALL VERTICAL DIMENSIONS SHOWN ARE MINIMUM. FEET ARE ADJUSTABLE TO +1" MAXIMUM.
MANUFACTURER MUST BE NOTIFIED IF UNIT WILL BE OPERATING ABOVE 2000' ALTITUDE.
CONSULT FACTORY FOR MANUFACTURED GAS.
Cleveland Range reserves right of design improvement or modification, as warranted.
VOLTS: 208/240
PHASE: 3
AMPS: 15
FREQ: 60 HZ
ELECTRICAL
SUPPLY
TYPE: NAT or LP
BTU PER CU. FT.:
1000 (NAT), 2500 (LP)
SUPPLY PRESSURE:
4" to 14" W.C.
BTU RATINGS:
190,000 per hour
60 GAL -
1010 LBS.
458 KG.
80 GAL -
1120 LBS.
508 KG.
100 GAL -
1325 LBS.
601 KG.
APPROX.
SHIPPING
WEIGHTS
GAS SUPPLY
(PIPING 3/4" NPT)
APPROVALS
AIR SUPPLY (PIPING 1/2" NPT)
AGA CGA NSF
H C
CH
5/8"Ø,
2 HOLES
ON
4" B.C.D.

SOLID

FOOT DETAIL

5
1/2"
3/8"
1" (MAX. ADJUSTMENT)
2"
RIGHT: 3", LEFT: 3"
REAR: 5"
(ALLOW 12" SPACE
MINIMUM ON LEFT
SIDE FOR SERVICE)
CLEARANCE
PRESSURE:
90 - 100 PSI
(only required for optional 3" dia.
piston draw-off valve)
HOT & COLD
WATER
H C
1/2" NPT CONNECTION
40-60 PSI PRESSURE
RIM BAR
3" DIA. BUTTERFLY VALVE

13"