OPERATING INSTRUCTIONS
Temperature Sensor
Senses temperature of product
Automatic Dump Valve
Empties kettle of either food product or wash water
Sight Glass
For checking water level of kettle jacket
Vacuum /Pressure Gauge
Indicates steam pressure inside steam jacket in PSI, as
well as vacuum in inches of mercury
Gas Shut-Off Valve
Air Quick Connect
Push yellow tab down to release air pressure before
disconnecting air hose
Kettle Filler Nozzle

A

Red Low Water Indicator Light
When lit, in the upright position, indicates kettle gas
burner has cut out and unit requires more water.
Occasional pulsing of this light is normal.
Green Heat Indicator Light
When lit, indicates gas burner is on; cycles on-off with
solid state controls.
Solid State Temperature Control Knob /
On-Off Toggle Switch
Controls electrical power to kettle. and allows operator to
select kettle heat increments from minimum, 1-10.
A setting of 7 or higher will boil water
Amber Ignition Failure Indicator Light
Indicates failure of heating system to ignite
(Used prior to July 2004)

B

Agitator Stop Button
Stops agitator in case of emergency
Agitator Start Switch
Starts agitator. Agitator power control switch must be ON
Agitator Power Switch
Allows power to agitator. When not in use, turn control
power OFF
Agitator Speed Control Switch
Turn clockwise until desired speed is reached

1

2

3

4

5

6

7

21 3

5

7

6

B

C

D

A

E

4

C

C

Power tilt control switch
Tilts kettle for pouring; some kettles have manual hand tilt
Reset circuit breaker
Protects power tilt system from overload. Push to reset

E

E

D

D

Fill Interrupt Switch
Interrupts water fill cycle
Potable Fill Water Switch
Selects hot or cold water
Fill Cycle Switch
Start/continue cycle switch
Product Discharge Valve Switch
Toggle momentary switch to desired valve opening
Water Meter Digital Counter (not shown)
Location may vary dependant on customer's specific
options
0123
NOTE:
Location of
switches may
vary dependant
on customers
specific options