VSET

program the voltage limiting of the Power Module’s output.

 

Syntax

VSET <ch>,<value>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the value to be set as the Power Module’s load

 

 

voltage limit. The lower limit of the programmed

 

 

value is 0. The upper limit of the programmed value

 

 

is the lower of VLIM and OVSET. If auto-polarity is

 

 

enabled, negative output values can be programmed

 

 

by preceding the value with a minus sigh.

 

Category

Settings

Type: Overlapped

VSET?

return the current programmed value of the Power Module’s load

 

voltage limit.

 

 

 

Syntax

VSET? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Settings

Type: Sequential

WHIGH

enable / disable window upper limits checks by the Power Module.

 

Syntax

WHIGH <ch>,<int>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

a value of “0” disables and a value of “1” enables

 

 

the Power Module’s upper limit window checks.

 

Category

Warnings

Type: Sequential

WHIGH?

return the state of the Power Module’s upper window check enable

 

flag. Result is “0” if disabled and “1” if enabled.

 

 

Syntax

WHIGH? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Warnings

Type: Sequential

WLOW

enable / disable window lower limits checks by the Power Module.

 

Syntax

WLOW <ch>,<int>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

a value of “0” disables and a value of “1” enables

 

 

the Power Module’s lower limit window checks.

 

Category

Warnings

Type: Sequential

WLOW?

return the state of the Power Module’s lower window check enable

 

flag. Result is “0” if disabled and “1” if enabled.

 

 

Syntax

WLOW? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Warnings

Type: Sequential

XMP 2600 Programming Manual rev. 1.1