Alphabetical reference

 

Commands and Queries Reference

CMASK

program the positive and negative edge masks of the Events Filter

 

Mechanism.

 

 

 

Syntax

CMASK <ch>,<int>,<int>

 

 

Parameters

The number of the Channel to which the masks are

 

 

being programmed.

 

 

 

The two integers are (respectively) the value of the

 

 

positive and negative masks. A bit value of “1”

 

 

enables the transition to generate an event while a bit

 

 

value of “0” disables it.

 

 

Category

Status

Type: Sequential

CMASK?

queries the

value of the positive and negative edge masks of the

 

Events Filter Mechanism. The query return two numbers: positive

 

mask and negative mask.

 

 

Syntax

CMASK? <ch>

 

 

Parameters

the number of the Channel to be queried.

 

Category

Status

Type: Sequential

CONF?

initiates a self-test of the XMP 2600 main control circuits. The tested

 

areas are: Controller Internal RAM, Tables Storage RAM, Settings

 

Storage Areas and Buffers RAM. The result of the self-test is reported

 

as a decimal number in the range 0 to 16 representing the bits of the

 

result register.

 

 

Syntax

CONF?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

CONF?

initiates a self-test of a Power Module. The tested areas are: Controller

 

Internal RAM, control circuit XMP 2600, analog section reference

 

voltage, D/A circuit and analog MUX. The result of the self-test is

 

reported as two decimal numbers in the range 0 to 255 representing

 

the bits of the result registers.

 

 

Syntax

CONF? <ch>

 

 

Parameters

the number of the Power Module to be tested.

 

Category

Status

Type: Sequential

The self-test is a lengthy operation that is carried out in the background. The CONF? Query initiates a self-test and returns the result of the previously executed self-test.