Advanced Features

Advanced Features

Workpoint window warning

4Advanced

Features

This chapter introduces some of the advanced features of the XMP 2600 and provides guidelines on the usage of those features.

Workpoint window warning

Usage guidelines

Power Modules of the XMP 2600 can monitor their outputs and warn the user if the output values exceed a defined range. The window warning thresholds that define the aforementioned range have both a high value (Vhigh for voltage and Ihigh for current) and a low value (Vlow for voltage and Ilow for current).

The following sections describe how to use the workpoint window warning feature of the XMP 2600.

Setting the window thresholds

Programming the window thresholds is done using the following commands:

VHIGH <ch>,<value>

for the high voltage

 

 

V

 

 

threshold

 

 

Vmax

Vhigh

 

 

 

 

 

 

 

 

IHIGH <ch>,<value>

for the high current

Vset

 

range

 

 

 

Vlow

Ihigh

 

threshold

 

 

 

 

 

 

 

Ilow

range

 

 

 

 

 

 

VLOW <ch>,<value>

for the low voltage

 

 

Imin

Imax

 

threshold

 

 

 

Iset

I

ILOW <ch>,<value>

for the low current threshold

 

 

 

 

 

The high threshold values can range from the set point (Vset or Iset) to the rating value (Vmax or Imax).

The low threshold values can range from 0 to the set point value (Vset or Iset).

Enabling the window thresholds

The high and low thresholds can be enabled or disabled, in pairs, using the commands: WHIGH <ch>,{10} (use 1 to enable and 0 to disable)

and

WLOW <ch>,{10} (use 1 to enable and 0 to disable)