Xantrex Technology XMP 2600 manual Commands and Queries Reference, Alphabetical reference

Models: XMP 2600

1 93
Download 93 pages 36.85 Kb
Page 63
Image 63

Alphabetical reference

 

Commands and Queries Reference

GRP?

return the

current definition of the group of Power Modules. The

 

response is made up of two decimal numbers (each in the range 0 to

 

255) being the high (sent first) and low parts of a 16-bit word. Each

 

bit in the response represents one Power Module (see GRP command

 

for details on bit values).

 

 

Syntax

GRP?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

IALL?

return output current measurements of all installed Power Modules.

 

The response is a series of values - one for each installed Power

 

Module, separated with “,”, starting with the lower numbered module.

 

Syntax

IALL?

 

 

Parameters

none

 

 

Category

Read-back

Type: Sequential

ID?

return the identification string: ‘XANTREX XMP 2600’.

 

Syntax

ID?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

IHIGH

program the upper window warning level for the output current of the

 

Power Module.

 

 

Syntax

IHIGH <ch>,<value>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the value to be set as the upper window warning

 

 

level for the output current. The upper limit of the

 

 

programmed value is IMAX. The lower limit of the

 

 

programmed value is ISET.

 

 

Category

Warnings

Type: Sequential

IHIGH?

return the current settings for the upper window warning level of the

 

output current of the Power Module. The response is a <value>.

 

Syntax

IHIGH? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

warnings

Type: Sequential

50

XMP 2600 Programming Manual rev. 1.1

Page 63