Image 52

Commands and Queries Reference

Categories

Status

Reporting

Commands

and Queries

Synch.

Commands

and Queries

*CLS

clears all Event Status Registers.

*ESE

assign new value to the Standard Event Status Enable Register.

*ESE?

return the value of the Standard Event Status Enable Register.

*ESR?

return the value of the Standard Event Status Register.

*IST?

return the current value of the Individual Status bit as defined by IEEE

 

488.1.

*PRE

assign new value to the Parallel Poll Enable Register.

*PRE?

return the value of the Parallel Poll Enable Register.

*PSC

controls whether or not the XMP 2600 will clear all the Event Enable

 

Registers and the 488.2 SRQ and Parallel Poll Enable Registers at Power

 

On.

*PSC?

return the value of the Power On Status Clear Enable Flag.

*SRE

assign new value to the Service Request Enable Register

*SRE?

return the value of the Service Request Enable Register.

*STB?

return the value of the Status Byte Register.

CALDT?

return the Calibration Date of a Power Module.

CESE

assign new value to the Channels Event Status Enable Register.

CESE?

return the value of the Channels Event Status Enable Register.

CMASK

program the positive and negative edge masks of the Events Filter

 

Mechanism.

CMASK?

queries the value of the positive and negative edge masks of the Events

 

Filter Mechanism.

CONF?

initiates a self-test of a Power Module

CSTS?

return the Power Module Status Structure data.

ERR?

return the last known Error Code of the XMP 2600 main controller.

ERR?

return the last know Power Module error code.

OPT?

return the Options Byte of the Power Module.

PEE

assign new value to the Primary Event Status Enable Register.

PEE?

return the value of the Primary Event Status Enable Register.

PER?

return the value of the Primary Event Status Register.

PSR?

return the value of the Primary Status Register.

SRQS?

return the Power Modules Summary Register.

*OPC

causes the XMP 2600 to suspend further parsing of commands and

 

queries until all pending operations have finished. Then, the Operation

 

Complete (opc) event bit of the Standard Event Status Register will be

 

set.

*OPC?

causes the XMP 2600 to suspend command parsing until all pending

 

operations have been finished. Then, the XMP 2600 response to the

 

Query with: “1”.

*WAI

prevent the XMP 2600 from parsing any further commands or queries

 

until all pending operations have finished.