Xantrex Technology XMP 2600 Warnings Commands and Queries, Trigger and Sync Commands and Queries

Models: XMP 2600

1 93
Download 93 pages 36.85 Kb
Page 51
Image 51
Warnings

Categories

Warnings

Commands

and Queries

Read-Back Queries

Trigger and

Sync

Commands

and Queries

 

 

Commands and Queries Reference

IHIGH

program the upper window warning level for the output current of the

 

 

Power Module.

IHIGH?

return the current settings for the upper window warning level of the

 

 

output current of the Power Module.

ILOW

program the lower window warning level for the output current of the

 

 

Power Module.

ILOW?

return the current settings for the lower window warning level of the

 

 

output current of the Power Module

VHIGH

program the upper window warning level for the load voltage of the

 

 

Power Module.

VHIGH?

return the current settings for the upper window warning level of the load

 

 

voltage of the Power Module.

VLOW

program the lower window warning level for the load voltage of the

 

 

Power Module.

VLOW?

return the current settings for the lower window warning level of the load

 

 

voltage of the Power Module

WHIGH

enable / disable window upper limits checks by the Power Module.

WHIGH?

return the state of the Power Module’s upper window check enable flag.

WLOW

enable / disable window lower limits checks by the Power Module.

WLOW?

return the state of the Power Module’s lower window check enable flag.

IALL?

return output current measurements of all operative Power Modules

ILOAD?

return output current measurement of the Power Module.

IOUT?

return output current measurement of the Power Module.

POWER?

return the XMP 2600 delivered output power.

VALL?

return load voltage measurements of all operative Power Modules.

VLOAD?

return load voltage measurement of the Power Module.

VOUT?

return output voltage measurement of the Power Module.

 

 

 

 

 

 

For their internal use (fault and warning detection), the Power Modules

 

 

 

generate a new read-back value every 40 mS.

 

 

 

The Main Controller is updated with new values (available for readback,

 

 

 

10 times a second.

 

 

 

 

 

*TRG

toggles the state of the Global Output Enable Flag

ARM

program a Power Module to the Armed state in which further SET and

 

 

PROT programming will be stored with no immediate effect of the output

 

 

of the Power Module.

ARM?

return the state of the Power Module.

SYNC

program the Power Module’s Sync Pulse Generation Enable Event.

SYNC?

return the current Sync Pulse Generation Event for the Power Module.

TRIG

program the Power Module’s reaction to a software or hardware trigger.

TRIG?

return the current reaction to trigger for the Power Module.

TRIGER

send a global trigger (to all Power Modules).

TRIGER

send a trigger to the Power Module.

38

XMP 2600 Programming Manual rev. 1.1

Page 51
Image 51
Xantrex Technology XMP 2600 manual Warnings Commands and Queries, Trigger and Sync Commands and Queries, Read-Back Queries