Xantrex Technology 815-2012, 815-3024, 815-3012, 815-2024 Inverter Operation Using the Front Panel

Models: 815-2024 815-2012 815-3012 815-3024

1 96
Download 96 pages 4.41 Kb
Page 26
Image 26
Freedom Inverter/Charger Operation

Freedom SW 3K2K InvChg Owners Guide.book Page 12 Wednesday, October 9, 2013 1:34 PM

Freedom Inverter/Charger Operation

Inverter Operation Using the Front Panel

IMPORTANT: Review the “Important Safety Instructions” on page iv before operating the inverter/charger.

Once the inverter/charger is installed, you can operate it in invert mode.

To operate in invert mode from the front panel:

1.Press the INVERTER ENABLE button on the Freedom SW on the front panel. The INVERTER ENABLED LED illuminates and connected loads will be energized.

2.Note that if AC is present and being passed through, the INVERTER ENABLED LED will still illuminate to indicate inverter mode has been enabled. However, AC will continue to be passed through to the loads until conditions exist that cause AC to be disqualified, in which case the unit will transition to invert mode and power up critical loads.

3.Connect AC input power.

The charger automatically starts up when qualified AC power is connected.

To operate the inverter with the System Control Panel, refer to “Operating the Freedom SW with the SCP” on page 15.

4.Disconnect AC power from inverter input by opening the breaker or disconnect.

5.Place a load on the inverter. For example, plug a 100-watt light bulb into an outlet that the inverter is powering. Press the INVERTER ENABLE button on the Freedom SW. The INVERTER ENABLED LED illuminates. The inverter should run the load using battery power.

6.To test the charger, reconnect the AC input power to allow AC to the AC input. The AC/Charger On LED should start flashing after a brief delay. Any AC loads previously powered by the inverter will also work at this time.

NOTE: On dual input models, only AC Input L1 needs to be powered for the unit to operate.

7.Remove the AC input power. The inverter/charger should transfer to invert mode immediately. (The transfer relay will make a clicking sound and the INVERTER ENABLED LED will illuminate.) Loads should continue to operate uninterrupted.

If any part of this test fails, determine the cause before using the unit.

8.Monitor the Freedom SW Front Panel.

The indicator lights on the front panel show you the operating status of the Freedom SW. A description of the lights is provided in Table 1.

If none of the front panel lights are on, see “Troubleshooting” on page 65.

Table 1 Front Panel Lights

Light

 

 

 

Illuminated

Color

Status

Action (or Status Item)

 

 

 

 

INVERTER

Steady

If utility and generator AC is

You can run your appliances

ENABLED

Green

unavailable and operating

from the inverter.

 

 

conditions are met, the

 

 

 

Freedom SW will produce

 

 

 

AC voltage to power loads.

 

GEN SUPPORT

Flashing

The inverter is assisting a

You can run your appliances

 

Green

generator in powering loads.

from the inverter.

 

 

12

 

 

Freedom SW Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 26
Image 26