Configuring the Freedom SW using the SCP

the Xanbus SCP displays the basic settings by default. To view the advanced settings, you must perform a special keypress (see “Selecting Advanced Settings From the Device Setup Screen” on page 43).

NOTE:

This keypress enables the advanced settings for every device in the system. After performing the keypress, Advanced Settings appears in the list and Basic Settings disappears.

FIRE AND ELECTRICAL SHOCK HAZARD

The advanced settings are intended for qualified installation/service personnel only. Before changing advanced settings, you must be familiar with the settings and the system-wide impact of changing those settings. Setting parameters incorrectly could damage connected equipment (such as batteries) or could severely affect the performance of your system. Incorrect charging configuration can lead to battery damage and risk of fire.

Failure to follow these instructions can result in minor or moderate injury.

The Freedom SW advanced settings include menus for configuring:

Inverter settings (see page 46).

Charger settings (see page 48).

AC transfer limit settings (see page 52).

Generator support settings (see page 53).

Stacking operation, including customizing the default model name of the Freedom SW, and setting its network device number. Setting the device number is important when multiple Freedom SWs are on the Xanbus network and sharing connections such as AC loads, utility grid, and generator. The device number is also used when configuring paralleled Freedom SWs for Master-Slave operation (see page 54).

Restoring default settings (see page 57) and other advanced features (see page 57).

Freedom SW advanced menu screen lists status information and settings which require that you understand and plan for the changes you make. You may not have to adjust these settings as part of regular operation.

The SCP shows the Freedom SW basic menu by default. To view the advanced settings menu, you have to activate it by following the procedure below.

To select the Advanced Settings menu screen:

1.On the FSW3012 00:Setup screen (Figure 21), press the Enter, Up arrow, Down arrow buttons simultaneously to make Advanced Settings appear in the list.

2.On the FSW3012 00:Setup screen, press the down arrow button until

Advanced Settings is highlighted.

 

 

42

 

 

Freedom SW Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 56
Image 56
Xantrex Technology 815-3024, 815-3012, 815-2012 Fire And Electrical Shock Hazard, Configuring the Freedom SW using the SCP