Freedom SW 3K2K InvChg Owners Guide.book Page 71 Wednesday, October 9, 2013 1:34 PM
Troubleshooting
Table 4 Fault Messages
Fault |
|
|
|
|
Number | Message | Fault Type | Cause | Solution |
|
|
|
|
|
F44 | Battery Over | Automatic | Battery temperature is over | Stop charging if necessary. |
| Temperature |
| 140 °F (60 °C). | Check cable connections. |
|
|
| Poor battery compartment | Check battery voltage/current and |
|
|
| ventilation. | temperature. If battery is not accepting |
|
|
|
| charge, it may need to be replaced. |
|
|
|
| Check for excessive ambient temperature |
|
|
|
| and adequate ventilation in the battery |
|
|
|
| compartment. |
|
|
|
|
|
|
| Automatic | BTS may be damaged. | If the unit displays a temperature of over |
|
|
|
| 212 °F (100 °C), the BTS will need to be |
|
|
|
| replaced. |
|
|
|
|
|
F47 | DC Under Voltage | Automatic | Immediate battery under | Check battery condition (short or open |
| (Immediate) |
| voltage fault. | cells) and ensure correct voltage. |
|
|
|
| Battery state charge or capacity is so low |
|
|
|
| that the DC voltage collapses when |
|
|
|
| inverter load is applied. |
|
|
|
| Inverter load is so large that the DC |
|
|
|
| voltage collapses when inverter load is |
|
|
|
| applied. |
|
|
|
|
|
|
| 71 |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|