Xantrex Technology 815-2012 ACIn Settings, Configuring the Freedom SW using the SCP, Description

Models: 815-2024 815-2012 815-3012 815-3024

1 96
Download 96 pages 4.41 Kb
Page 66
Image 66
ACIn Settings

Freedom SW 3K2K InvChg Owners Guide.book Page 52 Wednesday, October 9, 2013 1:34 PM

Configuring the Freedom SW using the SCP

ACIn Settings

The ACIn Settings menu configures the voltage and frequency limits for AC Input quantification range. These are the limits at which the Freedom SW considers input voltage qualified—that is, suitable for charging batteries or powering loads. If the input voltage is not qualified according to these settings, the Freedom SW transfers from using AC input to inverting.

Table 15 ACIn Settings Menu Description

Item

Description

 

 

AC1 Breaker

Sets the AC1 (Grid) breaker size, based on the size of the breaker installed

 

on AC1. The installed breaker size must not exceed the capacity of the

 

upstream distribution panel. The Freedom SW limits the maximum input

 

current to this setting by derating its charging current to an equivalent of

 

80% of the AC breaker size. If the connected loads exceed the AC1

FSW3012 00: ACIn Settings

ACIn Breaker

[30A]

ACIn Lo Volt

[95V]

ACIn Hi Volt

[135V]

ACIn Lo Freq

[55Hz]

ACIn Hi Freq

[65Hz]

Follow procedures on “To select and change a configurable setting:” on page 33 to change the settings.

 

breaker setting, the AC breaker trips. The breaker may not trip if grid

 

support is enabled and battery voltage is above the Grid Supp Volts

 

setting, or if peak load shave is enabled and the load shave time window is

 

active.

 

 

AC1 Lo Volt

Minimum acceptable input voltage level from the utility mains.

 

NOTE: It is recommended to leave this setting to its default value and not

 

to set it to the maximum allowed. Doing so might inadvertently derate

 

charging power in jurisdictions where the nominal AC mains voltage or

Figure 27 ACIn Settings Menu Screen

Table 14 Setting Defaults and Ranges

Model

Freedom SW 2012 / 3012

Freedom SW 2024 / 3024

 

 

 

 

 

 

 

Item

Default

Min

Max

Default

Min

Max

 

 

 

 

 

 

 

AC1 Breaker

30A

5A

30A

30A

5A

30A

 

 

 

 

 

 

 

AC1 Lo Volt

95V

78V

115V

95V

78V

115V

 

 

 

 

 

 

 

AC1 Hi Volt

135V

125V

140V

135V

125V

140V

 

 

 

 

 

 

 

AC1 Lo Freq

55V

44V

59V

55V

44V

59V

 

 

 

 

 

 

 

AC1 Hi Freq

65V

61V

70V

65V

61V

70V

 

 

 

 

 

 

 

 

 

 

generator output is at 110 volts.

 

 

AC1 Hi Volt

Maximum acceptable input voltage level from the utility mains.

 

 

 

 

AC1

Lo

Freq

Minimum acceptable utility mains input frequency.

 

 

 

 

AC1

Hi

Freq

Maximum acceptable utility mains input frequency.

 

 

52

 

 

Freedom SW Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 66
Image 66
Xantrex Technology 815-2012 Configuring the Freedom SW using the SCP, ACIn Settings Menu Description, Model, Default