Configurable Settings Status
FSW3012 00: Setup
Mode |
|
| Invert | |
Battery | 11.8V | N/A | ||
Load | 915W |
| 120V | 7A |
AC In | 0V |
| 0A | 0Hz |
Advanced Settings |
| |||
Inverter |
|
| [Enabled] | |
Search Mode |
| [Disabled] | ||
Charger |
|
| [Disabled] | |
Force Chg State |
|
| ||
Equalize |
|
| [Disabled] | |
Desired Mode |
| [Standby] |
Clear Faults Warnings
View Device Info
FSW3012 00: Adv Settings
Inverter Settings
Charger Settings
AC Settings
GEN Support
Stacking
Restore Defaults
Adv Features
[*Enabled] [Disabled] [*Disabled] [Enabled]
[*Disabled] [Enabled]
[*No Float] [Float] [Bulk] [Disabled]
[*Standby] [Operating]
FSW3012 00: Dev Info
View Fault Log
View Warning Log
View Event Log
FSW3012 00: Inv Settings
Low Batt Cut Out | [11.0] |
LBCO Delay | [10sec] |
Hi Batt Cut Out | [15.5V] |
Search Watts | [50W] |
Search Delay | [2sec] |
| |
|
|
FSW3012 00: Chg Settings | |
Batt Type | [Flooded] |
Custom Settings |
|
Batt Capacity | [440Ah] |
Max Chg Rate | [100%] |
Charge Cycle | |
ReCharge Volts | [12.5V] |
Absorb Time | [180min] |
Auto Chg Enable | [Enabled] |
Default Batt Temp | [Warm] |
|
| FSW3012 00: Cust Settings | ||
|
| Eqiz Support | [Enabled] | |
1 |
| Eqiz Voltage | [16.0V] | |
| ||||
|
| Bulk Voltage | [14.4V] | |
|
| Absorb Voltage | [14.4V] | |
|
| Float Voltage | [13.5V] | |
|
| BattTempComp | ||
|
|
|
|
|
[*Flooded] | [Gel] [AGM] | [Custom] | ||
[2StgNoFloat] | ||||
[*Enabled] | [Disabled] |
| ||
[*Warm] | [Hot] [Cold] |
|
Appears only when
1Equalize support is Enabled.
Figure 22 Menu Map of the Freedom SW Advanced Settings 1
|
| 44 |
|