Freedom SW 3K2K InvChg Owners Guide.book Page 25 Wednesday, October 9, 2013 1:34 PM
Reading the Freedom SW Device Setup Screen
The Freedom SW Device Setup menu screen displays
The Freedom SW Device Setup menu screen has two segments. The first segment (lines 2 to 5) displays status information and appears first in the screen’s initial four lines. The second segment (lines 6 to 15) contains selectable fields when the Down arrow button is pressed (scrolling down the device setup screen). These selectable fields are configurable, meaning their values can be changed from within the setup screen or they bring up another screen (another level of configuration). For information on how to
Operating the Freedom SW with the SCP
Select Device | FSW3012 00: Setup |
| ||
System Settings | Mode |
| Invert | |
FSW3012 00 | Battery | 11.8V | N/A | |
XAGS 00 | Load | 900W | 120V | 7A |
XSCP | AC In | 0V | 0A | 0Hz |
2 Press Enter | 1 Scroll down | 3 Press these |
to bring up the | using the Down | buttons to scroll |
device setup | arrow button. | up and down the |
screen. |
| Device Setup |
|
| fields. |
|
| Complete list Freedom SW Device |
|
| Setup fields. |
configure the Freedom SW inverter/charger, see “Configuring the Freedom SW using the SCP” on page 28.
To view the Freedom SW Setup menu screen:
1.On the Select Device screen, press the down arrow button until the FSW3012 001 is highlighted.
2.Then, press Enter to display the
FSW3012 00: Setup screen which is the device setup menu screen.
3.Press the Up and Down arrow buttons view status information fields and move between selectable fields.
FSW3012 00: Setup
Mode |
| Invert | |
Battery | 11.8V | N/A | |
Load | 900W | 120V | 7A |
AC In | 0V | 0A | 0Hz |
Configurable Settings Status
FSW3012 00: Setup
Mode |
|
| Invert | |
Battery | 11.8V | N/A | ||
Load | 900W |
| 120V | 7A |
AC In | 0V |
| 0A | 0Hz |
Advanced Settings |
| |||
Inverter |
|
| [Enabled] | |
Search Mode |
| [Enabled] | ||
Charger |
|
| [Enabled] | |
Force Chg State |
|
| ||
Equalize |
|
| [Disabled] | |
Desired Mode |
| [Standby] |
Clear Faults Warnings
View Device Info
Basic Settings
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
Line 7
Line 8
Line 9
Line 10
Line 11
Line 12
Line 13
Line 14
Line 15
1.Typical device ID for a single installed Freedom Inverter/Charger. If there are more than one, the device name FSW3012 is followed by 01, 02, et cetera.
* appears only when Enter, Up, and Down arrow buttons are pressed together.
|
| 25 |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|