Xantrex Technology 815-2012 Troubleshooting, Number, Message, Fault Type, Cause, Solution

Models: 815-2024 815-2012 815-3012 815-3024

1 96
Download 96 pages 4.41 Kb
Page 86
Image 86
Manual background

Freedom SW 3K2K InvChg Owners Guide.book Page 72 Wednesday, October 9, 2013 1:34 PM

Troubleshooting

Table 4 Fault Messages

Fault

 

 

 

 

Number

Message

Fault Type

Cause

Solution

 

 

 

 

 

F48

DC Under Voltage

Automatic

Voltage at the DC input

Check for the correct battery voltage at the

 

(Fault)

 

terminals is below the Low

inverter's DC input terminals.

 

 

 

Battery Cut Out (LBCO)

Check for external DC loads on the

 

 

 

setting for 10 seconds.

batteries.

 

 

 

 

Check condition of batteries and recharge

 

 

 

 

if necessary.

 

 

 

 

Reduce the Low Battery Cut Out (LBCO)

 

 

 

 

setting.

 

 

 

 

Battery bank capacity may be inadequate

 

 

 

 

for the loads in the system.

 

 

 

 

 

F49

DC Over Voltage

Automatic

Voltage at the DC input

Clear the fault and attempt restart. Ensure

 

 

 

terminals is above the High

battery voltage is 10–16 VDC at Freedom

 

 

 

Battery Cut Out Setting

SW terminals. Check all other charging

 

 

 

 

source outputs, battery cables.

 

 

 

 

 

 

 

72

 

 

Freedom SW Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 86
Image 86
Xantrex Technology 815-2012, 815-3024, 815-3012, 815-2024 Troubleshooting, Number, Message, Fault Type, Cause, Solution