Freedom SW 3K2K InvChg Owners Guide.book Page 38 Wednesday, October 9, 2013 1:34 PM
Configuring the Freedom SW using the SCP
An overview of the Freedom SW menu structure is shown below. The SCP displays the Freedom SW basic settings menu.
Configurable Settings Status
FSW3012 00: Setup
Mode |
|
| Invert | |
Battery | 11.8V | N/A | ||
Load | 915W |
| 120V | 7A |
AC In | 0V |
| 0A | 0Hz |
Inverter |
|
| [Enabled] | |
Search Mode |
| [Disabled] | ||
Charger |
|
| [Disabled] | |
Force Chg State |
|
| ||
Equalize |
|
| [Disabled] | |
Desired Mode |
| [Standby] |
Clear Faults Warnings
View Device Info
Basic Settings
[*Enabled] [Disabled] [*Disabled] [Enabled]
[*Disabled] [Enabled]
[*No Float] [Float] [Bulk] [Disabled]
[*Standby] [Operating]
FSW3012 00: Dev Info
View Fault Log
View Warning Log
View Event Log
FSW3012 00: Basic Settings
Batt Type | [Flooded] |
Batt Capacity | [440Ah] |
Max Chg Rate | [100%] |
Charge Cycle | |
ReCharge Volts | [12.5V] |
AC In Breaker | [30A] |
Low Batt Cut Out | [11.0V] |
[*Flooded] [Gel] [AGM] [Custom]
Follow procedures on “To select and change a configurable setting:” on page 33 to change the settings.
Figure 20 Menu Map of the Freedom SW Basic Settings
|
| 38 |
|
| Freedom SW Owner’s Guide |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|