Operating the Freedom SW with the SCP
Table 4 Freedom SW Device Setup Screen Operating States (Modes)
State (Mode) | Displayed When... |
|
|
Invert | The Freedom SW is supplying power to loads by inverting power |
| from the batteries. AC input from the utility or generator is absent or |
| out of nominal range. |
|
|
Qualifying AC | The Freedom SW is determining if AC input is within a usable |
| voltage and frequency range. Qualifying AC is also displayed |
| when the Freedom SW is awaiting application of AC power or a |
| command to enable invert mode. |
|
|
Charging | The Freedom SW is charging the batteries from qualified AC input |
| from the utility grid or a generator. The charge state is in transition |
| to either bulk, absorption, float, or equalize. AC input is also passed |
| through to the load while charging. |
|
|
Bulk | The Freedom SW is bulk charging the batteries from qualified AC |
| input from the utility grid or a generator. AC input is also passed |
| through to the load while bulk charging. |
|
|
Absorption | The Freedom SW is absorption charging the batteries from qualified |
| AC input from the utility grid or a generator. AC input is also passed |
| through to the load while absorption charging. |
|
|
ABS Finish | One Freedom SW unit has completed the absorption stage and is |
| waiting for other Freedom SWs in the system to complete |
| absorption. This status can occur only when there is another |
| Freedom SW also charging the battery. |
|
|
Float | The Freedom SW is float charging the batteries from qualified AC |
| input from the utility grid or a generator. The Freedom SW is set for |
| |
| while float charging. |
|
|
Fault | The Freedom SW has an active fault. The Fault/Warning light on the |
| Xanbus SCP is on. |
|
|
State (Mode) | Displayed When... |
|
|
Gen Support | There is AC input from the generator, and the Freedom SW is |
| supporting the generator by supplying additional power to the |
| critical loads. See “Gen Support” on page 53. |
|
|
Search | Search mode is enabled and the Freedom SW is standing by, waiting |
| to begin inverting. See “Changing Configurable Settings From The |
| Device Setup Menu Screen” on page 32. |
|
|
Passthru | The AC connected to the AC1 or AC2 input is passing directly |
| through the Freedom SW to the loads. The batteries are not being |
| charged in this state. |
|
|
Equalize | Equalization has been turned on and the Freedom SW is equalizing |
| the batteries after completing a full charge cycle. |
|
|
|