Table 4 Fault Messages

 

 

Fault

 

 

 

 

 

 

 

 

 

 

 

 

 

Number

Message

Fault Type

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F64

AC overload

Escalating Auto Fault.

Persistent excessive

Avoid loads with long surge current.

 

 

 

 

 

 

 

Must occur 3 times in 60

inverter current above rated

 

 

 

 

 

 

 

 

 

 

seconds before becoming a

current.

 

 

 

 

 

 

 

 

 

 

manual fault.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F68

Transformer Over

Automatic

Same as F57.

Same as F57.

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F69

External Sync Failed

Automatic

When Series stacking— the

Install the Stacking cable to connect the

 

 

 

 

 

 

 

 

 

Stacking cable is not

two inverter/chargers.

 

 

 

 

 

 

 

 

 

installed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F70

Unique Dev# Needed

Automatic

When stacking (Series or

Change the Device Number of one unit.

 

 

 

 

 

 

 

 

 

Parallel)—if two units have

See “Setting the Device Number” on page

 

 

 

 

 

 

 

 

 

the same Device Number.

56.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F71

Too Many Masters

Automatic

When stacking (Series or

Change one unit to a Slave unit. See Stack

 

 

 

 

 

 

 

 

 

Parallel)—if two units are

Mode under “Stacking Configuration

 

 

 

 

 

 

 

 

 

configured as Master units.

Menu” on page 54 in Table 17.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F73

Transformer Temp

Automatic

Temperature sensor is

Service required.

 

 

 

 

 

 

unreadable

 

 

damaged.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F74

Other Unit Invert

Automatic

When stacking (Series or

Clear the primary fault on the unit that

 

 

 

 

 

 

Fault

 

 

Parallel)—if one of the

caused this fault.

 

 

 

 

 

 

 

 

 

units encounters a fault that

 

 

 

 

 

 

 

 

 

 

 

 

needs to be resolved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 