Table 6 Setting Defaults and Ranges

Freedom SW 3K2K InvChg Owners Guide.book Page 39 Wednesday, October 9, 2013 1:34 PM

Configuring the Freedom SW using the SCP

Table 6 Setting Defaults and Ranges

Model

Freedom SW 2012 / 3012

Freedom SW 2024 / 3024

 

 

 

 

 

 

 

 

 

Item

Default

 

Min

Max

Default

 

Min

Max

 

 

 

 

 

 

 

 

 

Batt Type

Flooded

 

Flooded, Gel,

Flooded

 

Flooded, Gel,

 

 

 

AGM, Custom

 

 

AGM, Custom

 

 

 

 

 

 

 

 

 

Batt Capacity

250Ah

 

50Ah

2000Ah

250Ah

 

50Ah

1000Ah

2000-watt models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Batt Capacity

440Ah

 

 

 

440Ah

 

 

 

3000-watt models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Chg Rate

100%

10%

100%

100%

10%

100%

 

 

 

 

 

 

 

 

 

Charge Cycle

3Stage

 

3Stage,

3Stage

 

3Stage,

 

 

 

2StgNoFloat

 

 

2StgNoFloat

 

 

 

 

 

 

 

 

 

ReCharge Volts

12.5V

 

11.0V

13.5V

25.0V

 

22.0V

27.0V

 

 

 

 

 

 

 

 

 

AC1 Breaker

30A

 

5A

30A

30A

 

5A

30A

 

 

 

 

 

 

 

 

 

Low Batt Cut Out

10.5V

 

10.0V

12.0V

21.0V

 

20.0V

24.0V

 

 

 

 

 

 

 

 

 

Table 7 Basic Settings

Item

Description

 

 

Batt Type

Sets the system battery chemistry and type: Flooded, AGM, Gel, and

 

Custom.

 

Selecting Custom displays the Custom Settings item, which

 

allows you to adjust the settings for each charging stage.

Batt Capacity

Selects the system battery capacity in amp hours. Setting the battery

 

capacity to 0 resets the charging current to its default values.

 

Zero Ah battery capacity implies there is no absorption exit current

 

criteria and absorption only exits when the absorption timer (default

 

3hrs, range 1min-8hr) expires.

Max Chg Rate

Sets the percentage of the maximum DC output current that is

 

available to the charger. The maximum DC output current for

 

different models is:

 

Freedom SW 2012 —100 ADC

 

Freedom SW 3012 —150 ADC

 

Freedom SW 2024 —50 ADC

 

Freedom SW 3024 —75 ADC

 

If multiple Freedom SWs are charging the same battery bank, set

 

each inverter's Max Chg Rate to 1/n of the desired charge rate

 

(where n is the number of inverter/chargers).

Charge Cycle

Sets the charging method: 3-Stage(bulk, absorption, float) or

 

2StgNoFloat (bulk, absorption, no float).

ReCharge Volts

Sets the recharging volts to tell the charger to initiate charging when

 

the battery drains past the value setting.

AC In Breaker

Set the breaker limit of incoming AC.

 

 

Low Batt Cut Out

Low Battery Cut Out (LBCO) controls when the inverter stops

 

producing AC output due to a low battery voltage condition. The

 

inverter will stop producing AC output only after this level has been

 

reached for the period of time set by the LBCO Delay. This setting is

 

not temperature compensated.

 

 

 

 

 