Xantrex Technology 815-2024, 815-3024 manual General Troubleshooting Guidelines, 97-0019-01-01

Models: 815-2024 815-2012 815-3012 815-3024

1 96
Download 96 pages 4.41 Kb
Page 79
Image 79
Troubleshooting

Freedom SW 3K2K InvChg Owners Guide.book Page 65 Wednesday, October 9, 2013 1:34 PM

Troubleshooting

General Troubleshooting Guidelines

This section will help you narrow down the source of any problem you may encounter. Please read the following troubleshooting steps:

1.Check for a warning or fault message on the Xanbus SCP or a fault code on the inverter information panel. If a message is displayed, record it immediately.

2.As soon as possible, record the conditions at the time the problem occurred. These details should include the following information:

loads the Freedom SW was running or attempting to run

battery condition at the time of failure (battery voltage or temperature, for example), if known

recent sequence of events (for example, charging had just finished, utility grid had failed but the inverter did not come on)

any known unusual AC input factors such as low voltage or unstable generator output

extreme conditions which may have existed at the time (temperature or moisture, for example).

3.Attempt the solution indicated in these guidelines.

4.If your inverter information panel or Xanbus SCP is not displaying a Fault light, check the following list to make sure that the present state of the installation allows proper operation of the unit. Read these guidelines carefully.

Is the Freedom SW located in a clean, dry, adequately ventilated area?

Have the AC input breakers opened? If so, your pass-through load may have exceeded the rating of one or more of the input breakers.

Are the battery cables adequately sized and short enough? See the Installation Guide for more information.

Is the battery in good condition and are all DC connections tight?

Are the AC input and output connections and wiring in good condition?

Are the configuration settings correct for your particular installation?

Are the display panel and the communications cable properly connected and undamaged?

Is the battery temperature sensor and its cable properly connected and undamaged?

5.Contact Customer Service for further assistance. Please be prepared to describe details of your system installation and provide the model and serial number of the unit. See the front and/or back of the manual for contact information.

 

 