Troubleshooting

Table 5 provides a detailed description of the warning messages and solutions. If you are unable to resolve the problem after referring to this table, contact your dealer or Customer Service.

Table 5 Warning Messages

Fault

 

 

 

 

Number

Message

Fault Type

Cause

Solution

 

 

 

 

 

W48

DC under voltage

Automatic

Voltage at the DC input

Check for the correct battery voltage at the

 

(Warning)

 

terminals is below the Low

inverter's DC input terminals.

 

 

 

Battery Cut Out (LBCO)

Check for external DC loads on the

 

 

 

setting.

batteries.

 

 

 

 

Check condition of batteries and recharge

 

 

 

 

if necessary.

 

 

 

 

Reduce the Low Battery Cut Out (LBCO)

 

 

 

 

setting.

 

 

 

 

Battery bank capacity may be inadequate

 

 

 

 

for the loads in the system.

 

 

 

 

 

W69

AGS not connected

Automatic

The GenSup Mode setting

Install a Xanbus AGS on the network or

 

 

 

is enabled but there is no

disable the GenSup Mode setting.

 

 

 

AGS connected in the

 

 

 

 

Xanbus network.

 

 

 

 

 

 

 

 