Table 3 Device Setup Screen Status Information

Freedom SW 3K2K InvChg Owners Guide.book Page 26 Wednesday, October 9, 2013 1:34 PM

Operating the Freedom SW with the SCP

 

 

Field 1

 

Field 2

Field 3

Field 4

Line 1 FSW3012 00: Setup

 

 

Line 2 Mode

 

Invert

Line 3 Battery

11.9V

-8.8A

N/A

Line 4 Load

915W

120V

7A

Line 5

 

60Hz

Field 5

 

 

 

Field 6

 

 

 

Field 7

 

 

 

 

Field 8

Field 9

Field 10

Table 3 Device Setup Screen Status Information

Line 4

Label: Load

 

Field 5: Total power drawn by AC loads connected to the unit.

 

Field 6: Inverter output voltage at load terminals of one inverter/

 

charger unit.

 

Field 7: Sum of all current drawn out by the AC loads.

 

 

Line 5

Label: AC In

 

Field 8: AC input voltage at AC In terminals of the inverter/charger.

 

Field 9: Sum of all current drawn into one inverter/charger unit.

 

Field 10: AC input frequency

 

 

STBY/ON Fault Clear

Press momentarily to clear all faults on all devices on the network.

button

Press and hold for five seconds to switch all devices in the network

 

between operating and safe modes.

 

 

Enter, Up arrow,

Switches between Basic Settings and Advanced Settings.

Down arrow buttons

 

(pressed

 

simultaneously)

 

 

 

Table 3 Device Setup Screen Status Information

Line 1

Line 2

Line 3

Label: “FSW3012 00: Setup

Label: Mode

Field 1: Freedom SW operating mode or “operating state” (see Table 4 on page 27).

Label: Battery

Field 2: Total battery current. Negative value if the battery is discharging and positive value when charging.

Field 3: Battery voltage

Field 4: Battery temperature. Displays the highest temperature when reading multiple inverters that are installed. Displays N/A when there is no BTS attached.

 

 