SWING OPERATION

Begin air conditioner operation before performing this procedure.

To select SWING Operation

Press the SWING button (Fig. 6 T).

The SWING Display (Fig. 7 c) will light.

Each time the SWING button is pressed, the swing operation will change in the following order.

Up/down swing operation Left/right swing operation

Swing operation stops Up/down/left/right swing operation

To stop SWING Operation

Press the SWING button and select STOP.

Airflow direction will return to the setting before swing was begun.

About Swing Operation

Up/down swing: Swing operation begins using the following range according to the current airflow direc- tion.

Airflow direction is 1–4 (for cooling, dry).

With the upper airflow-direction louver in the horizontal position, the lower airflow-direction louver moves (swings) to direct airflow to a wide area.

Airflow direction is 3–6 (for heating).

With the airflow-direction louvers set for down- ward or straight down airflow, airflow is directly mainly at the floor.

Left/right swing: The airflow-direction louvers move (swing) in the left/right airflow direction.

Up/down/left/right swing: The airflow-direction louvers move (swing) in both the up/down and left/right airflow directions.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

If the SET button(Vertical) is pressed during the up/ down swing operation, the up/down swing operation will stop and if the SET button(Horizontal) is pressed during the left/right swing operation, the left/right swing operation will stop.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium.

The COIL DRY Operation will operate for 20 minutes after pressing the COIL DRY button and it will stop automatically.

To select COIL DRY Operation

Press the COIL DRY button (Fig. 6 L) during operation or when it stops.

The COIL DRY Display (Fig. 7 a) will light. Then it will disappear after 20 minutes.

To cancel COIL DRY Operation

Press the START/STOP button (Fig. 6 Q) during COIL DRY

Operation.

The COIL DRY Display (Fig. 7 a) will go out . Then the operation stops.

About COIL DRY Operation

Press the COIL DRY button again during COIL DRY Operation, COIL DRY Opera- tion can be reset.

The COIL DRY Operation cannot get rid of the existed mould or bacterium, and it has no sterilization effect either.

En-10

Page 11
Image 11
Friedrich MW24Y3F Coil DRY Operation, To select Swing Operation Press the Swing button T, About Swing Operation

MW24Y3F specifications

The Friedrich MW24Y3F is a standout in the world of portable air conditioning units, designed for both residential and commercial applications. With its sleek design and advanced features, this model offers exceptional cooling capabilities while ensuring energy efficiency and user comfort.

One of the main features of the MW24Y3F is its powerful cooling capacity. With a BTU rating of 24,000, it is well-suited for larger rooms or open spaces, making it an ideal choice for users seeking effective temperature control without the noise and complexity of traditional central air conditioning systems. This unit can easily cool spaces of up to 1,500 square feet, providing a refreshing respite from sweltering heat.

The MW24Y3F employs cutting-edge technologies that enhance its performance and user experience. Notably, it incorporates inverter technology, allowing for more efficient energy consumption. By adjusting the compressor speed as per the cooling demand, it reduces energy usage while maintaining consistent temperatures. This translates to lower electricity bills and a reduced carbon footprint, making it an environmentally friendly choice.

Another significant characteristic is its user-friendly interface. The unit features a digital display and remote control, enabling users to adjust settings effortlessly from across the room. Additionally, the MW24Y3F includes a programmable timer, allowing for automatic operation based on the user’s schedule, further enhancing convenience.

The air conditioning unit also prioritizes air quality, integrating a multi-stage filtration system that captures dust, allergens, and other pollutants. This feature is particularly beneficial for those with respiratory issues or allergies, providing cleaner, healthier air in the living or work environment.

In terms of installation, the MW24Y3F is designed for flexibility. It can be set up as a window or portable unit, giving users options based on their property layout and personal preferences. Its compact size allows it to fit well in various spaces without compromising aesthetics.

In summary, the Friedrich MW24Y3F combines high cooling capacity, energy efficiency, user-friendly features, and air quality improvement technologies, making it an excellent choice for anyone looking to enhance their indoor climate control.