PROPERTY DAMAGE HAZARDS

PROPERTY DAMAGE HAZARDS

FIRE DAMAGE HAZARDS:

Read the Installation/Operation Manual for this air conditioning unit prior to operating.

Use air conditioner on a single dedicated circuit within the specified amperage rating.

Connect to a properly grounded outlet only.

Do not remove ground prong of plug.

Do not cut or modify the power supply cord.

Do not use extension cords with the unit.

Failure to follow these instructions can result in fire and minor to serious property damage.

WATER DAMAGE HAZARDS:

Improper installation maintenance, or servicing of the air conditioner unit, or not following the above Safety Warnings can result in water damage to personal items or property.

Insure that the unit has a sufficient pitch to the outside to allow water to drain from the unit.

Do not drill holes in the bottom of the drain pan or the underside of the unit.

Failure to follow these instructions can result in result in damage to the unit and/or minor to serious property damage.

INTRODUCTION

This service manual is designed to be used in conjunction with the operation and installation manual provided with each unit.

This service manual was written to assist the professional HVAC service technician to quickly and accurately diagnose and repair any malfunctions of this product.

This manual, therefore, will deal with all subjects in a general nature. (i.e. All text will pertain to all models).

IMPORTANT: It will be necessary for you to accurately identify the unit you are servicing, so you can be certain of a proper diagnosis and repair. (See Unit Identification.)

 

Compressor

 

 

Liquid Filter Driers

 

 

Condenser Coil

Front Cover

 

 

Discharge Air

 

 

 

 

System Controls

 

 

 

Outdoor Grille

 

 

 

Evaporator Coil

 

 

Sleeve

Return Air Grille/Filter

 

 

 

 

Blower Wheel

 

 

 

 

Blower Motor

Basepan

Condenser Fan Blade

 

 

 

 

4

Page 5
Image 5
Friedrich R-410A service manual Introduction, Property Damage Hazards, Fire Damage Hazards, Water Damage Hazards