Set theTimer Stop Time

F

AUTO FAN

SET POINT

FRR144

The display shows a normal system. Press and hold the MIN button (Figure

4)for 3 seconds. Note the Timer start - stop times may be set even when the system is in the Schedule mode.

AM

OFF

FRR145

Use the or button to adjust the hour. Press the TIMER SET button (Figure 4) to advance to the Minutes section.

OFF

FRR146

Use the or button to adjust the minutes. Press the TIMER SET button (Figure 4) within 15 seconds to exit and save the setting. The timer is now set to stop at 11:55 AM. The display returns to normal.

Turning the TIMER ON once the time and day, the start and top times have been set:

TIMER

Press the SCHEDULE button once and let go.

NOTE: See the following TIMER ON/OFF scenarios.

Timer ON Scenarios

Scenario 1

F

AUTO FAN

SET POINT

FRR156

The display shows a normal operating system.

FRR157

If the Timer function is turned ON during the Timer’s OFF time, the icon illuminates. The control system immediately turns the unit OFF.

Scenario 2

F

AUTO FAN

SET POINT

FRR158

The display shows a normal operating system.

F

AUTO FAN

SET POINT

FRR159

If the Timer function is turned ON during the Timer’s ON time, the icon illuminates. The control system immediately turns the unit OFF.

16

Page 17
Image 17
Friedrich SQ05N10, SQ10N10, SQ08N10, SQ06N10, EQ08N11 manual Set theTimer Stop Time, Timer on Scenarios