DIM Function

There are three separate display brightness levels, AUTO, 20% and full (100%). To change the DIM setting, press the Power button for three seconds.

FRR192

The 1 indicates a DIM setting of Auto (factory default on new units). Use

the or buttons to change the setting.

FRR193

The 2 indicates a DIM setting of 20%. Press the TIMER SET button within 15 seconds to save the setting. Button inactivity for more than 15 seconds causes the display to time out and return to the normal operating display.

FRR194

The 3 indicates a DIM setting of 100% (full brightness). Press the TIMER SET (Refer to Figure 8) button within 15 seconds to save the setting. Button inactivity for more than 15 seconds causes the display to time out and return to the normal operating display.

Alerts

When the ¿lter needs to be cleaned or replaced, the CHECKFILTER icon displays.

F

AUTO FAN

SET POINT

CHECK

FILTER

 

 

 

FRR118

The alert can be dismissed by pressing the

 

MODE and

SCHEDULE

for 3 seconds.

 

FAN

TIMER

 

Wait Icon

F

AUTO FAN

SET POINT

FRR120

The wait icon illuminates when the compressor lockout is active.

Control Panel Lock

To lock the front panel controls, press and hold the SPEED +

SCHEDULE buttons

 

FAN

TIMER

for 3 seconds. The lock icon

illuminates to indicate the locked status.

During lockout, none of the control panel buttons will operate.

F

AUTO FAN

SET POINT

To unlock, press and hold the SPEED +

FRR116

SCHEDULE buttons simultaneously for 3

FAN

TIMER

seconds.

 

External Control Status

The $MART icon illuminates to indicate that the system is being controlled

remotely, such as from a smart grid from a power company (for more information, see page 12).

SMART

F

AUTO FAN

SET POINT

$MART

FRR125

WiFi Connection

F

AUTO FAN

SET POINT

FRR126

The icon illuminates to indicate that the system is receiving a Wi-Fi connection (for more information, see page 10).

13

Page 14
Image 14
Friedrich EQ08N11, SQ10N10, SQ08N10, SQ05N10 DIM Function, Alerts, Wait Icon, Control Panel Lock, External Control Status