Friedrich SQ05N10, SQ10N10, SQ08N10 manual Method Of Charging / Repairs, Burn Hazard, Freeze Hazard

Models: EQ08N11 SQ06N10 SQ05N10 SQ08N10 SQ10N10

1 67
Download 67 pages 59.79 Kb
Page 32
Image 32
Method Of Charging / Repairs

Method Of Charging / Repairs

The acceptable method for charging the RAC system is the Weighed in Charge Method. The weighed in charge method is applicable to all units. It is the preferred method to use, as it is the most accurate.

The weighed in method should always be used whenever a charge is removed from a unit such as for a leak repair, compressor replacement, or when there is no refrigerant charge left in the unit. To charge by this method, requires the following steps:

1.Install a piercing valve to remove refrigerant from the sealedsystem. (Piercing valve must be removed from the system before recharging.)

2.Recover Refrigerant in accordance with EPA regulations.

BURN HAZARDWARNING

BURN HAZARD

Proper safety procedures must be followed, and proper protective clothing must be worn when working with a torch.

Failure to follow these procedures could

UHVXOWLQPRGHUDWHRUVHULRXVLQMXU\

3. Install a process tube to sealed system.

FREEZE HAZARDCAUTION

FREEZE HAZARD

Proper safety procedures must be followed, and proper protective clothing must be worn when working with liquid refrigerant.

Failure to follow these procedures could

UHVXOWLQPLQRUWRPRGHUDWHLQMXU\

4.Make necessary repairs to system.

5.Evacuate system to 200 microns or less.

6.Weigh in refrigerant with the property quantity of R410-A refrigerant.

7.Start unit, and verify performance.

Manual backgroundWARNING

BURN HAZARD

Proper safety procedures must be followed, and proper protective clothing must be worn when working with a torch.

Failure to follow these procedures could

UHVXOWLQPRGHUDWHRUVHULRXVLQMXU\

8. Crimp the process tube and solder the end shut.

31

Page 32
Image 32
Friedrich SQ05N10, SQ10N10, SQ08N10, SQ06N10, EQ08N11 manual Method Of Charging / Repairs, Burn Hazard, Freeze Hazard