920-198-00

STEP 4 CHECKING WIRING AND PLUMBING: Check all wiring and plumbing inside and outside of the wall to be sure none will be broken where the hole is to be cut.

STEP 5 HOLE CONSTRUCTION: Depending upon size of unit to be installed, lay out the hole dimensions per the chart below. Cut and frame in hole to finished dimensions. Use 2" x 4" material for framing and follow the suggested typical installations in Figure C, D, or E.

NOTE: IF THE WALL CONSTRUCTION IS TYPICAL FRAME OR 2 x 4 STUDDING WITH BRICK OR STONE VENEERS, LOCATE THE HOLE NEXT TO ONE OF THE STUDS. FOR MASONRY, CONCRETE OR CINDER BLOCK WALLS, LOCATE HOLE FOR CONVENIENCE.

Figure D

BRICK VENEER CONSTRUCTION

SHIM VOID SPACES AT TOP AND

SIDES WITH WOOD AS REQUIRED

CAULK ALL SIDES

CABINET

FINISHED

SMALL

MEDIUM

LARGE

DIMENSION

CHASSIS

CHASSIS

CHASSIS

A

16 316"

18 316"

20 38"

B

26 316"

26 316"

28 14"

NOTE: THESE DIMENSIONS ARE FOR FINISHED HOLE SIZE.

Figure C

FRAME WALL CONSTRUCTION

CAULK ALL SIDES

CABINET

ELECTRICAL

RECEPTACLE (SEE FIG. E FOR

LOCATION NOTE)

SHIM THE VOID

SPACE AT THE

TOP AND SIDES

WITH WOOD AS REQUIRED

ELECTRICAL RECEPTACLE

(SEE FIGURE E FOR LOCATION NOTE)

Figure E

SOLID MASONRY CONSTRUCTION

CAULK

ALL SIDES

CABINET

MORTAR

ELECTRICAL

RECEPTACLE

POINT "X"

NOTE: ELECTRICAL RECEPTACLE LOCATION FROM POINT "X" MUST BE WITHIN A MAXIMUM RADIUS OF 69" FOR 115V UNITS AND 45" FOR 230V UNITS.

16

Page 16
Image 16
Friedrich SS14, SS16 Brick Veneer Construction, Finished Small Medium Large Dimension Chassis, Frame Wall Construction