STEP 4 CHECKING WIRING AND PLUMBING: Check all wiring and
plumbing inside and outside of the wall to be sure none will be
broken where the hole is to be cut.
STEP 5 HOLE CONSTRUCTION: Depending upon size of unit to be
installed, lay out the hole dimensions per the chart below. Cut
and frame in hole to ¿nished dimensions. Use 2" x 4" material for
framing and follow the suggested typical installations in Figure
C, D, or E.
NOTE: IFTHEWALLCONSTRUCTIONISTYPICALFRAME
OR2x4STUDDINGWITHBRICKORSTONE VENEERS,
LOCATETHEHOLENEXTTOONEOFTHESTUDS.FOR
MASONRY, CONCRETE OR CINDER BLOCK WALLS,
LOCATE HOLE FOR CONVENIENCE.
NOTE: THESE DIMENSIONS ARE FOR FINISHED HOLE SIZE.
FINISHED
DIMENSION
SMALL
CHASSIS
MEDIUM
CHASSIS
LARGE
CHASSIS
A16
3»16"18
3»16"20
3»8"
B26
3»16"26
3»16"28
1»4"
CABINET
CAULK ALL SIDES
ELECTRICAL
RECEPTACLE
(SEE FIG. E FOR
LOCATION NOTE) SHIM THE VOID
SPACE AT THE
TOP AND SIDES
WITH WOOD AS
REQUIRED
Figure C
FRAMEWALLCONSTRUCTION
CAULK ALL SIDES
CABINET
SHIM VOID SPACES AT TOP AND
SIDES WITH WOOD AS REQUIRED
ELECTRICAL RECEPTACLE
(SEE FIGURE E FOR
LOCATION NOTE)
Figure D
BRICK VENEER CONSTRUCTION
MORTAR
ELECTRICAL
RECEPTACLE
POINT "X"
CABINET
CAULK
ALL SIDES
Figure E
SOLID MASONRY CONSTRUCTION
NOTE: ELECTRICAL RECEPTACLE LOCATION FROM
POINT "X" MUST BE WITHIN A MAXIMUM RADIUS OF
69" FOR 115V UNITS AND 45" FOR 230V UNITS.