Friedrich YS09 Through-the-wallInstallations, Before, After, Top View, Figure A, Detail

Models: YS09

1 56
Download 56 pages 23.15 Kb
Page 15
Image 15
Through-the-wall Installations

920-198-01

Through-the-wall Installations

The following instructions apply to wood, masonry, brick, concrete or cinder block wall construction

Figure AWARNING

Falling Object Hazard

Not following Installation Instructions for mounting your air conditioner can result in property damage, injury, or death.

STEP 1 Follow steps 1, 2, 3 and 4 of the "STANDARD SASH WINDOW INSTALLATION" instructions beginning on page 10.

STEP 2 CABINET PREPARATION – Remove the sill plate from the cabinet by removing the two nuts and screws retaining the sill plate. Note that the chassis retainer is secured by a right side nut and screw (See Detail 1, Figure A.) Bend the tabs of the sill plate down into its channel at both ends of the plate or cut them off (See Detail 2, Figure A.) Turn the sill plate end to end, 180° and reinstall. Reverse the orientation of nuts and screws so that the head of screw is on bottom of cabinet facing up and nut is on top facing down (See Detail 3, Figure A.) Insure that the chassis retainer is reinstalled as shown in the detail.

STEP 3 WALL PREPARATION – The maximum wall thickness permis- sible without special construction is determined by the model size to be installed. THE OUTSIDE CABINET CONDENSER-AIR-

INTAKE-LOUVERS MUST NOT BE BLOCKED BY EXTENDING INSIDE THE WALL AREA. Observe the maximum wall thickness shown in the chart and diagram in Figure B.

SPECIAL INSTRUCTIONS FOR EXTRA THICK WALLS – For installation in walls exceeding the maximum thickness shown in the chart, the following suggested construction may apply.

Figure A

CABINET

BEFORE

AFTER

 

 

 

SCREW

 

 

(2 REQUIRED)

 

 

 

NUT

 

DETAIL 1

(2 REQUIRED)

SILL

 

PLATE

NOTE: HOLES

 

MOVED TO

 

 

 

TURN SILL PLATE

BACK SIDE

 

 

 

END TO END

NUT

DETAIL 3

 

(2 REQUIRED)

 

 

 

RETAINER, CHASSIS

SCREW

 

THIS SIDE ONLY

(2 REQUIRED)

 

 

SCREW AND NUT

 

 

ORIENTATION NOW

 

 

REVERSED

 

DETAIL 2

 

 

BEND TABS DOWN

 

Figure B EXTRA THICK WLL CONSTRUCTION

MAXIMUM WALL THICKNESS

CONDENSER

AIR INTAKE

LOUVERS

 

 

 

TOP VIEW SHOWING

MODEL

A

 

BEVELED SIDES FOR

 

 

 

AIR INTAKE. WALL

SMALL CHASSIS

7

"

BELOW UNIT MUST BE

MEDIUM CHASSIS

7

"

BEVELED ALSO.

LARGE CHASSIS

15

"

 

TOP VIEW

CONDITIONED ROOM SIDE AIR

 

2" MINIMUM

 

BOTH SIDES

 

CONDENSER AIR

 

INTAKE LOUVERS

CONDENSER AIR

NOTE: Condenser air inlets

OUTLET / REJECTED

and outlet must be unobstruct-

HEATED AIR

ed to avoid the recirculation of

rejected heated air.

 

15

Page 15
Image 15
Friedrich YS09 Through-the-wallInstallations, Before, After, Top View, Figure A, Detail, Falling Object Hazard