Friedrich YS09 Figure D BRICK VENEER CONSTRUCTION, Finished, Small, Medium, Large, Dimension

Models: YS09

1 56
Download 56 pages 23.15 Kb
Page 16
Image 16
Figure D

920-198-01

STEP 4 CHECKING WIRING AND PLUMBING: Check all wiring and plumbing inside and outside of the wall to be sure none will be broken where the hole is to be cut.

STEP 5 HOLE CONSTRUCTION: Depending upon size of unit to be installed, lay out the hole dimensions per the chart below. Cut and frame in hole to ¿nished dimensions. Use 2" x 4" material for framing and follow the suggested typical installations in Figure C, D, or E.

NOTE: IF THE WALL CONSTRUCTION IS TYPICAL FRAME OR 2 x 4 STUDDING WITH BRICK OR STONE VENEERS, LOCATE THE HOLE NEXT TO ONE OF THE STUDS. FOR MASONRY, CONCRETE OR CINDER BLOCK WALLS, LOCATE HOLE FOR CONVENIENCE.

Figure D

BRICK VENEER CONSTRUCTION

SHIM VOID SPACES AT TOP AND

SIDES WITH WOOD AS REQUIRED

CAULK ALL SIDES

CABINET FINISHED

FINISHED

SMALL

MEDIUM

LARGE

DIMENSION

CHASSIS

CHASSIS

CHASSIS

A

16 3»16"

18 3»16"

20 3»8"

B

26 3»16"

26 3»16"

28 1»4"

NOTE: THESE DIMENSIONS ARE FOR FINISHED HOLE SIZE.

Figure C

FRAME WALL CONSTRUCTION

CAULK ALL SIDES

CABINET SMALL

ELECTRICAL

RECEPTACLE (SEE FIG. E FOR

LOCATION NOTE)

SHIM THE VOID

SPACE AT THE

TOP AND SIDES

WITH WOOD AS REQUIRED

MEDIUM ELECTRICAL RECEPTACLE

(SEE FIGURE E FOR

LOCATION NOTE)

Figure E

SOLID MASONRY CONSTRUCTION

CAULK

ALL SIDES

CABINET

MORTARLARGE

ELECTRICAL

RECEPTACLE

POINT "X"

NOTE: ELECTRICAL RECEPTACLE LOCATION FROM POINT "X" MUST BE WITHIN A MAXIMUM RADIUS OF 69" FOR 115V UNITS AND 45" FOR 230V UNITS.

16

Page 16
Image 16
Friedrich YS09 operation manual Figure D BRICK VENEER CONSTRUCTION, Finished, Small, Medium, Large, Dimension, Chassis