Friedrich YS09 operation manual Figure F TYPICAL INSTALLATION

Models: YS09

1 56
Download 56 pages 23.15 Kb
Page 17
Image 17
Figure F TYPICAL INSTALLATION

920-198-01

Figure F TYPICAL INSTALLATION

TRIM MOULDING

SCREW #12A x 2"

LONG (USE 3)

SILL PLATE GUIDE CHANNEL

INSIDE WALL SURFACE

CAULK ALL SIDES WEATHER TIGHT

Manual background" SLOPE DOWN

NOTE: SUPPORT BRACKETS MAY BE OMITTED

FROM THROUGH-THE-WALL INSTALLATIONS IF THE

CABINET IS SECURED AS FOLLOWS. DRILL 2 HOLES

IN EACH SIDE AND INSTALL 4 FASTENERS (2 EACH

SIDE). USE #12 x 2" SCREWS, TOGGLE BOLTS OR

EXPANSION ANCHOR BOLTS AS SHOWN IN STEP 7.

CABINET

SUPPORT BRACKETS (AVAILABLE AS OPTIONAL ACCESSORY)

SCREW #12 x 2" LONG, USE ONE EACH BRACKET.

DRILL 5»32 DIA. PILOT HOLES.

STEP 6 Slide the cabinet into the hole far enough to allow the guide- channel of the sill plate to contact the inside wall surface (See Figure F).

STEP 7 Drill three (3) 5 »32" dia. pilot holes through holes in sill-plate into framing and install three (3) #12A x 2" long screws (See Figure F).

NOTE: ALTERNATE FASTENERS WHICH MAY BE USED FOR SECURING THE SILL PLATE IN THE WALL AND THE SUPPORT BRACKETS TO THE OUTSIDE WALL (NOT FURNISHED BUT AVAILABLE AT LOCAL HARDWARE STORE).

EXPANSION ANCHOR BOLT

MOLLY OR TOGGLE BOLT

STEP 8 Drill two (2) 5 »32" dia. pilot holes each cabinet side at the locations shown (see Figure F) and install four (4) #12A x 2" screws (Item

#4, page 9). Provided that Step 5 (hole construction) provides a sturdy mount with solid vertical studs, no support brackets are required. The installation must support the weight of the unit plus an additional weight of 400 pounds on the rear of the cabinet.

If support brackets are available, they can certainly be used for through-the-wall installations as shown in Figure F.

If the reliability of the wall is in question, a window installation kit which includes support brackets can be ordered (see Accessories).

STEP 9 If desired, trim around the cabinet on the room side with a suitable

frame moulding furnished by the installer (see Figure F).

STEP 10 Complete the installation by following steps 13 through 18 of SASH WINDOW INSTALLATION INSTRUCTIONS, pages 13-14.

STEP 11 Refer to the OPERATION SECTION for instructions.

NOTICE

Instructions for mounting sleeve with slope must be observed to prevent entry of water into room.