Friedrich ZQ10 A10B manual Electrical Parts, Overload Protector, Compressor, Capacitor

Models: ZQ10 A10B

1 28
Download 28 pages 45.5 Kb
Page 7
Image 7
2.3 ELECTRICAL PARTS

2.3 ELECTRICAL PARTS

2.3.1 OVERLOAD PROTECTOR

1. Remove the cabinet. (Refer to section 2.1.2)

2. Remove the nut which fastens the terminal cover.

3. Remove the terminal cover. (See Figure 7)

4. Remove all the leads from the overload protector.

5. Remove the overload protector.

6. Re-install the component by referring to the removal procedure, above.

Figure 7

2.3.2 COMPRESSOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Discharge the refrigerant system using a FreonTM

Recovery System.

If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

3. Remove the overload protector. (Refer to section 2.3.1)

4. After purging the unit completely, unbraze the suction and discharge tubes at the compressor

connections.

5. Remove the 3 nuts and the 3 washers whichFigure 8 fasten the compressor.

6.Remove the compressor. (See Figure 8)

7.Re-install the components by referring to the removal procedure, above.

2.3.3 CAPACITOR

1. Remove the control box. (Refer to section 2.1.3)

2. Remove the knobs and the screw which fasten control panel from control box.

3. Remove the screw which is located in the front.

4. Open the bottom side of control box.

5. Remove the screw and the clamp which fasten the capacitor.

6. Disconnect all the leads of capacitor terminals.

7. Re-install the components by referring to the removal procedure, above. (See Figure 9)

Figure 9

— 7—

Page 7
Image 7
Friedrich ZQ10 A10B manual Electrical Parts, Overload Protector, Compressor, Capacitor