Friedrich ZQ10 A10B Room Air Conditioner Voltage Limits, Name Plate Rating, Minimum, Maximum

Models: ZQ10 A10B

1 28
Download 28 pages 45.5 Kb
Page 21
Image 21

ROOM AIR CONDITIONER VOLTAGE LIMITS

NAME PLATE RATING

 

MINIMUM

 

MAXIMUM

 

 

 

 

 

 

 

115V

 

103.5V

 

126.5V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPLAINT

 

CAUSE

 

REMEDY

 

 

 

 

 

 

 

Fan motor will not run.

No power

Check voltage at outlet. Correct if none.

 

 

 

 

 

 

 

 

 

Power supply cord

Check voltage to rotary switch. If none, check

 

 

 

 

 

power supply cord. Replace cord if circuit is open.

 

 

 

 

 

 

 

 

 

Rotary switch

Check switch continuity. Refer to wiring diagram

 

 

 

 

 

for terminal identification. Replace switch if none

 

 

 

 

 

defective.

 

 

 

 

 

 

 

 

 

Wire disconnected or

Connect wire. Refer to wiring diagram for terminal

 

 

connection loose

identification. Repair or replace loose terminal.

 

 

 

 

 

 

 

 

 

Capacitor (Discharge

Test capacitor.

 

 

capacitor before testing.)

Replace if not within ±10% of manufacturer's

 

 

 

 

 

rating. Replace if shorted, open, or damaged.

 

 

 

 

 

 

 

 

 

Will not rotate

Fan blade hitting shroud or blower wheel hitting

 

 

 

 

 

scroll. Realign assembly.

 

 

 

 

 

Units using slinger ring condenser fans must

 

 

 

 

 

have 2/9 to 1/4 inch clearance to the base. If it is

 

 

 

 

 

the base, shim up the bottom of the fan

 

 

 

 

 

motor with mounting screw(s).

 

 

 

 

 

Check fan motor bearings; if motor shaft will not

 

 

 

 

 

rotate, replace the motor.

 

 

 

 

 

 

Fan motor runs

Revolves on overload.

Check voltage. See limits on this page. If not within

intermittently.

 

 

 

limits, call an electrician.

 

 

 

 

 

Test capacitor.

 

 

 

 

 

Check bearings. Does the fan blade rotate freely?

 

 

 

 

 

If not, replace fan motor.

 

 

 

 

 

Pay attention to any change from high speed to

 

 

 

 

 

low speed. If the speed does not change, replace

 

 

 

 

 

the motor.

 

 

 

 

 

 

 

— 21—

Page 21
Image 21