![2.4 REFRIGERATING CYCLE](/images/new-backgrounds/33208/3320817x1.webp)
2.4 REFRIGERATING CYCLE
CAUTION
Discharge the refrigerant system using a FreonTM Recovery System.
If there is no valve to attach the recovery system, install one (such as a WATCO
2.4.1 CONDENSER
1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the 3 screws which fasten the brace.(Refer to section 2.2.1)
3. Remove the screw which fastens the cover cond. 4. Remove the 5 screws which fasten the condenser and shroud.
5. After discharging the refrigerant completely,Figure 14 unbraze the interconnecting tube at the condenser
connections.
6.Remove the condenser carefully.
7.
(See Figure 14)
2.4.2 EVAPORATOR
1. Remove the cabinet. (Refer to section 2.1.2)
2.Remove the 2 screws which fasten the evaporator.
3.Move the evaporator sideways carefully.
(Refer to section 2.2.1)
4. After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections.
5. Remove the evaporator carefully.
6.
Figure 15
2.4.3 CAPILLARY TUBE
1.Remove the cabinet. (Refer to section 2.1.2)
2.After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube.(See caution above)
3.Remove the capillary tube.
4.
— 9—