INSTALLATION INSTRUCTIONS
Electrical connection (non-Canada) - 3 wire cord
3-wire receptacle
(NEMA type
WARNING
ELECTRICAL SHOCK HAZARD Failure to disconnect power source before servicing could result in personal injury or even death.
1Turn off power supply to outlet.
2Remove the screw securing the terminal block access cover in the lower corner on the back of the dryer.
3Install a
4Thread an UNPLUGGED,
5Attach the power cord neutral (center wire) conductor to the SILVER colored center terminal on the terminal block. Tighten the screw securely.
6Attach the remaining two power cord outer conductors to the outer, BRASS colored terminals on the terminal block. Tighten both screws securely.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/conductor at
30 AMP |
|
NEMA | Neutral |
| (center wire) |
Access cover
screw
Terminal
block
Line 2
(BRASS terminal)
Neutral
(SILVER terminal)
Line 1
(BRASS terminal)
Internal ground (GREEN screw)
Install
strain relief here
Terminal screw
recovery slot
NOTE
If a terminal screw falls during cord installation, it can be retrieved in the terminal screw recovery slot below the access panel.
DO NOT remove
Neutral
internal ground in
connections.
7Follow manufacturer’s guidelines for firmly securing the strain relief and power cord.
8Reinstall the terminal block cover.
IMPORTANT
If moving dryer from a
a
terminal
15