INSTALLATION REQUIREMENTS
Manufactured or mobile home installation
1Installation MUST conform to current Manufactured Home Construction & Safety Standard, Title 24 CFR, Part
2Dryer MUST be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred.
3If dryer is exhausted through the floor and area beneath the mobile home is enclosed, the exhaust
system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure.
4Refer to previous sections in this guide for other important exhaust venting system requirements.
5When installing a gas dryer into a mobile home, a provision must be made for outside make up air. This provision is to be not less than twice the area of the dryer exhaust outlet.
6Installer MUST anchor this (1) dryer or (2) dryer mounted on pedestal to the floor with approved Mobile Home Installation Kit - P/N 137067200.
Clearance requirements
WARNING
EXPLOSION HAZARD
Do not install the dryer where gasoline or other
flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns.
IMPORTANT
DO NOT INSTALL YOUR DRYER:
1In an area exposed to dripping water or outside weather conditions.
2In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air.
3On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm).