Frigidaire 137134900B Electrical connection non-Canada - 4 wire cord, Installation Instructions

Models: 137134900B

1 68
Download 68 pages 28.72 Kb
Page 16
Image 16
Electrical connection (non-Canada) - 4 wire cord

INSTALLATION INSTRUCTIONS

Electrical connection (non-Canada) - 4 wire cord

4-wire receptacle

(NEMA type 14-30R)

terminal for 4-wire system.ground wire WARNING

ELECTRICAL SHOCK HAZARD Failure to disconnect power source before servicing could result in personal injury or even death.

1

Turn off power supply to outlet.

2

Remove the screw securing the terminal block

 

access cover in the lower corner on the back of the

 

dryer.

3

Install a UL-approved strain relief according to the

 

power cord/strain relief manufacturer’s instructions

 

in the power cord entry hole below the access

 

panel. At this time, the strain relief should be

 

loosely in place.

4

Thread an UNPLUGGED, UL-approved, 30 amp.

 

power cord, NEMA 14-30 type ST or SRDT, through

 

the strain relief.

5

Disconnect the internal (BLACK) dryer harness

 

ground wire from the (GREEN) ground screw next

 

to the terminal block.

6

Attach the ground (GREEN) power cord wire to the

 

cabinet with the ground (GREEN) screw. Tighten

 

the screw securely.

7

Move the internal dryer harness ground (BLACK)

 

wire to the terminal block and attach it along with

 

the neutral (WHITE) power cord wire conductor

 

to the center, SILVER colored terminal on the

 

 

Neutral

30 AMP

Ground

(WHITE wire)

 

(GREEN wire)

 

NEMA 14-30

 

 

 

Access cover

screw

Terminal

block

Line 2

(BRASS terminal)

Neutral

(SILVER terminal)

Line 1

(BRASS terminal)

Internal ground (GREEN screw)

Install

UL-approved

strain relief here

Terminal screw

recovery slot

NOTE

If a terminal screw falls during cord installation, it can be retrieved in the terminal screw recovery slot below the access panel.

terminal block. Tighten the screw securely.

8 Attach the RED and BLACK power cord conductors

to the outer, BRASS colored terminals on the

terminal block. Tighten both screws securely.

RED power wireneutral wire WARNING

ELECTRICAL SHOCK HAZARD

Do not make a sharp bend or crimp wiring/conductor at connections.

9Follow manufacturer’s guidelines for firmly securing the strain relief and power cord.

10Reinstall the terminal block cover.

Move internal ground (BLACK)

wire to neutral (SILVER)

terminal for 4-wire system.

GREEN

ground screw

GREEN

ground wire

BLACK or

RED power wire

Neutral terminal

WHITE

neutral wire

BLACK or RED

 power wire power wire

16

Page 16
Image 16
Frigidaire 137134900B Electrical connection non-Canada - 4 wire cord, Installation Instructions, Electrical Shock Hazard