Frigidaire 318201679 (0903), CPDS3085KF U.S.A, Electrical Connection to the Range

Models: CPDS3085KF 318201679 (0903)

1 40
Download 40 pages 46.11 Kb
Page 6
Image 6
4. Electrical Connection to the Range

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with an Electric Oven and a Gas Cooktop)

4. Electrical Connection to the Range

(U.S.A.)

Three Conductor Wire Connection to Range

If local codes permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord (see Figure 3):

1.Remove the 3 screws at the lower end of the rear wire cover, then bend the lower end of the rear wire cover (access cover) upward to expose range terminal connection block (see Figure 2).

2.Using the nuts supplied in the literature package, connect the neutral of the copper power supply cord to the center silver-colored terminal of the terminal block, and connect the other wires to the outer terminals. Match wires and terminals by color (red wires connected to the right terminal, black wires connected to the left terminal) (see figure 3).

3.Lower the terminal cover and replace the 3 screws.

Silver Colored Terminal

Red Wire

Terminal

Cord

Block

Mounting

 

 

Plate

Black

Neutral

Wire

(White Wire)

 

Grounding

 

Strap

A User Supplied

 

1 1/8" (2.9 cm) Dia.

 

Direct Connection

Strain-relief Must

 

To 240 V

Hole. Punch Out

Be Installed at This

Knockout for 1 3/8"

Location.

Receptacle

(3.5 cm) Dia. Cord

 

 

 

Figure 3

Kit Hole.

 

 

Four Conductor Wire Connection to Range

Where local codes does NOT permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord (see Figure 4):

1.Remove the 3 screws at the lower end of the rear wire cover, then raise the lower end of the rear wire cover (access cover) upward to expose range terminal connection block (see figure 2).

2.Remove the grounding strap from the terminal block and from the appliance frame.

3.Using the nuts supplied with the literature package, connect the ground wire (green) of the copper power supply cord to the frame of the appliance with the ground screw, using the hole in the frame where the ground strap was removed (see Figure 4).

4.Connect the neutral of the copper power supply cord to the center silver-colored terminal of the terminal block, and connect the other wires to the outer terminals. Match wires and terminals by color (red wires connected to the right terminal, black wires connected to the left terminal).

5.Lower the terminal cover and replace the 3 screws.

Terminal Block

Silver Colored Terminal

Red

Wire

Black Wire

 

1 1/8" (2.9cm)

 

Dia. Direct

 

Connection

 

Hole. Punch

Neutral

Out Knockout

(White Wire)

for 1 3/8"

Ground (Bare

(3.5cm) Dia.

Cord Kit Hole.

Copper Wire)

A User Supplied

 

Strain-relief Must

 

Be Installed at This

 

Location

To 240 V Receptacle

NOTE: Be sure to remove the supplied grounding strap.

Figure 4

6

Page 6
Image 6
Frigidaire 318201679 (0903) U.S.A, Electrical Connection to the Range, Three Conductor Wire Connection to Range