Assemble the flexible connector from the gas supply pipe to the pressure regulator in the following order:
1.manual shutoff valve (not supplied)
2.1/2" nipple (not supplied)
3.1/2" flare union adapter (not supplied)
4.flexible connector (not supplied)
5.1/2" flare union adapter (not supplied)
6.1/2" nipple (not supplied)
7.pressure regulator (supplied)
The gas supply line to the shutoff valve should be 1/2"(1,27 cm) or 3/4"(1.9 cm) solid pipe.
The user must know the location of the main shutoff valve and have easy access to it.
When using flexible gas conduit on the range, allow sufficient slack to pull the range outside the cutout for cleaning or servicing.
NOTE: Do not allow the flexible conduit to get pinched between the wall and the range. To visually check, remove the range drawer.
Use
to |
|
|
appliance |
|
|
| to |
|
| gas | suppl |
|
| |
|
| y |
Shutoff Valve - |
| line |
|
| |
Open position |
|
|
Figure 10 |
|
|
Once regulator is in place, open the shutoff valve in the gas supply line. Wait a few minutes for gas to move through the gas line.
Leak testing of the appliance shall be conducted according to the manufacturer's instructions.
Check for leaks. After connecting the range to the gas supply, check the system for leaks with a manometer. If a manometer is not available, turn on the gas supply and use a liquid leak detector at all joints and connections to check for leaks.
Do not use a flame to check for leaks from gas connections. Checking for leaks with a flame may result in a fire or explosion.
All openings in the wall or floor where the range is to be installed must be sealed.
Tighten all connections if necessary to prevent gas leakage in the cooktop or supply line.
Disconnect this range and its individual shutoff valve from the gas supply piping system during any pressure testing of the system at test pressures greater than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).
Isolate the range from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).
6.LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/ Propane gas. It is shipped from the factory for use with natural gas.
If you wish to convert your range for use with LP/ Propane gas, use the supplied fixed orifices located in a bag containing the literature marked "FOR LP/PROPANE GAS CONVERSION." Follow the instructions packaged with the orifices.
The conversion must be performed by a qualified service technician in accordance with the manufacturer's instructions and all local codes and requirements. Failure to follow these instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion.
Failure to make the appropriate conversion can result in personal injury and property damage.
The supply line must be equipped with an approved manual shutoff valve. This valve should be located in the same room as the range and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the appliance.