Frigidaire CPDS3085KF Models with an Electric Oven and a Gas Cooktop, Example Junction Box

Models: CPDS3085KF 318201679 (0903)

1 40
Download 40 pages 46.11 Kb
Page 7
Image 7
Figure 5

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with an Electric Oven and a Gas Cooktop)

Direct Electrical Connection to the Circuit Breaker, Fuse Box or Junction Box

If the appliance is connected directly to the circuit breaker, fuse box or junction box, use flexible, armored or nonmetallic sheathed copper cable (with grounding wire). Supply a U.L. listed strain-relief at each end of the cable. At the appliance end, the cable goes through the Direct Connection Hole (see Figure 5) on the Cord Mounting Plate. Wire sizes (copper wire only) and connections must conform to the rating of the appliance.

A50A time-delay fuse or circuit breaker is recommended (minimum 40A).

Where local codes permit connecting the appliance- grounding conductor to the neutral (white) wire (see Figure 5):

1.Be sure that no power is supplied on the cable from residence.

2.Remove the grounding strap from the terminal block and from the appliance frame.

3.In the circuit breaker, fuse box or junction box:

a)Connect the green (or bare copper) wire, the white appliance cable wire, and the neutral (white) wire together.

b)Connect the 2 black wires together.

c)Connect the 2 red wires together.

Cable from Residence

Neutral

 

Black

(white) Wire

 

Wires

Red

 

 

Wires

 

 

 

 

Junction

 

 

Box

 

 

White Wire

Green

 

U.L.-listed Conduit

(or Bare Copper)

 

Connector (or CSA

Wire

Cable from

listed)

 

Appliance

 

NOTE: Be sure to remove the supplied grounding strap.

Figure 5

3-Wire (Grounded Neutral) Electrical System

(Example: Junction Box)

Where local codes DO NOT permit connecting the appliance-grounding conductor to the neutral (white) wire, or if connecting to 4-wire electrical system (see Figure 6):

1.Be sure that no power is supplied on the cable from residence.

2.Remove the grounding strap from the terminal block and from the appliance frame.

3.In the circuit breaker, fuse box or junction box:

a)Connect the white appliance cable wire to the neutral (white) wire.

b)Connect the 2 black wires together.

c)Connect the 2 red wires together.

d)Connect the green (or bare copper) grounding wire to the grounding wire of the circuit breaker, fuse box or junction box.

Cable from Residence

Green (or Bare

Copper) Wire

White Wire

Red

Wires

(Example: Junction Box)Black

Figure 6 – 4-Wire Electrical System Wires

Green (or Bare

Copper) Wire

White Wire

Junction

U.L.-listed Conduit

Box

Connector (or CSA

Cable from

listed)

Appliance

 

NOTE: Be sure to remove the supplied grounding strap.

Figure 6 – 4-Wire Electrical System

(Example: Junction Box)

7

Page 7
Image 7
Frigidaire CPDS3085KF Models with an Electric Oven and a Gas Cooktop, WireGrounded Neutral Electrical System